Order
Code
number
6.1
ROOM THERMOSTAT
6.2
MODE SET PRIORITY
7.1
IBH FUNCTION
7.2
IBH LOCATE
7.3
dT1_IBH_ON
7.4
t_IBH_DELAY
7.5
T4_IBH_ON
7.6
P_IBH1
7.7
P_IBH2
7.8
AHS FUNCTION
7.9
AHS_PUMPI CONTROL
7.10
dT1_AHS_ON
7.11
t_AHS_DELAY
7.12
T4_AHS_ON
7.13
EnSWITCHPDC
7.14
GAS_COST
7.15
ELE_COST
7.16
MAX_SETHEATER
7.17
MIN_SETHEATER
7.18
MAX_SIGHEATER
7.19
MIN_SIGHEATER
8.1
T1S_H.A_H
PREHEATING FOR
FLOOR-T1S
FLOOR DRYING UP
t_FIRSTFH
t_DRYUP
t_HIGHPEAK
12
t_DRYD
t_DRYPEAK
START TIME
State
Room thermostat type : 0=NON,1=MODESET,2=ONE
ZONE 3=DOUBLE ZONE
Select the priority mode in ROOM
THERMOSTAT:0=HEAT,1=COOL
Select the mode that IBH(BACKUP HEATER)can run:
0=HEAT+DHW,1=HEAT
The installation location of IBH(PIPE LOOP=0)
The temperature difference between T1S and T1 for
starting the backup heater.
The time that the compressor has run before starting
the first step backup heater.
The ambient temperature for starting the backup
heater.
Power input of IBH1
Power input of IBH2
Enable or disable the AHS(AUXILIARY HEATING
SOURCE) function:0=NON,1=HEAT,2=HEAT+DHW
Select the pump operating status when only AHS
runs:0=RUN,1=NOT RUN
The temperature difference between T1S and T1B
for starting the auxiliary heating source.
The time that the compressor has run before starting
the additional heating source
The ambient temperature for starting the additional
heating source
Enable or disable the function that heat pump and
auxiliary heating source switch automatically based on
running cost:0=NON,1=YES
Price of gas
Price of electricity
Maximum setting temperature of additional heating source
Minimum setting temperature of additional heating source
The voltage corresponding to the maximum setting
temperature of additional heating source
The voltage corresponding to the minimum setting
temperature of additional heating source
The target outlet water temperature for space
heating in holiday away mode
The setting temperature of outlet water during
first preheating for floor
The function of drying up the floor
Running time for first preheating of the floor
Temp-up days for floor drying up
Days for floor drying up
Temp-down days for floor drying up
Outlet temperature of floor drying up
The start time of floor drying up
42
Default
Unit
0
/
0
/
0(DHW=valid
/
) 1 (DHW=invalid)
0
/
5
°C
30
min
-5
°C
0
kW
0
kW
0
/
0
/
°C
5
30
min
-5
°C
0
/
0.85
€/m
3
0.20
€/kWh
80
°C
30
°C
10
V
3
V
25
°C
25
°C
/
/
72
HOUR
DAY
8
DAY
5
DAY
5
45
°C
Hour:the
present
time(not on
h/min
the hour +1,
on the hour
+2)
Minute:00
V.1