By inactivity we mean that the plumbing system remains stationary as there is no withdrawal of water
from the taps (i.e., holiday period).
If the plumbing system is subjected to a cleaning and sanitizing intervention, BravoFIL PLUS must
also be included in the intervention plan.
The sanitation intervention is part of the extraordinary maintenance interventions that must
be carried out exclusively by qualified personnel. If necessary, contact an Acqua Brevetti
SRL Technical Assistance Center (TAC).
A2.2 Maintenance schedule
Frequency
of operations
First year
Second year
Third year
Fourth year
Fifth year
BRAVOFIL PLUS – ENGLISH
Operation description
CARTRIDGE ASSEMBLY: Cleaning
O-RING: check tightness and, in case of leakage, replace
PRESSURE REDUCER AND MANOMETER
Check operation
SANITIZATION INTERVENTION
Annually; for periods of inactivity exceeding 30 days; when
replacing the filter cartridge
CARTRIDGE ASSEMBLY: Cleaning
O-RING: check tightness and, in case of leakage, replace
PRESSURE REDUCER AND MANOMETER
Check operation
SANITIZATION INTERVENTION
Annually; for periods of inactivity exceeding 30 days; when
replacing the filter cartridge
CARTRIDGE ASSEMBLY: Cleaning
O-RING: check tightness and, in case of leakage, replace
PRESSURE REDUCER AND MANOMETER
Check operation
SANITIZATION INTERVENTION
Annually; for periods of inactivity exceeding 30 days; when
replacing the filter cartridge
CARTRIDGE ASSEMBLY: Cleaning
O-RING: check tightness and, in case of leakage, replace
PRESSURE REDUCER AND MANOMETER
Check operation
SANITIZATION INTERVENTION
Annually; for periods of inactivity exceeding 30 days; when
replacing the filter cartridge
CARTRIDGE ASSEMBLY
Replace, if required
PRESSURE REDUCER AND MANOMETER
Check operation
SANITIZATION INTERVENTION
Annually; for periods of inactivity exceeding 30 days; when
replacing the filter cartridge