Multicyclone Total Head Loss Curve; Installation; Typical Installation - Waterco MultiCyclone 12 Manual De Instalación Y Funcionamiento

Ocultar thumbs Ver también para MultiCyclone 12:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

English
mULticYcLONe PLUs tOtAL heAD LOss cUrVe
MULTICYCLONE PLUS TOTAL HEAD LOSS CURVE
12.8/88.3
11.36/78.3
9.95/68.6
8.53/58.8
7.11/49.0
5.69/39.2
4.27/29.4
2.84/19.6
1.42/9.8
0
0
26.4/100
52.8/200
79.25/300
MultiCyclone 12

iNstALLAtiON

Be sure to comply with the local plumbing codes.
Be sure that all provisions for wastewater disposal meet local, state or national codes. do not
discharge water where it will cause flooding or damage.
If the incoming water pressure is higher than the maximum operating pressure of 50psi, a
pressure Regulating Valve (pRV) must be installed upstream of the filter inlet.
The PRV should be set to 90% of the maximum operating pressure of the tank.
If the incoming water flow is less than the filter's minimum flow requirements, the filter's filtration
efficiency will be affected, please consult Waterco.
105.6/400
132/500
158.5/600
Flow (gpm/lpm)
MultiCyclone 16

typical installation

1. position the filter as close to the Swimming pool / Spa as possible.
2. position the filter so that it is free from flooding, away from sumps, guttering, garden hollows,
etc.
3. position the filter so that the piping connections purge valve and air release valve is convenient
and accessible for operation, servicing and winterizing.
4. Ensure that the compliance label is facing the front to allow easy identification.
5. The filter should be placed on a level concrete slab, very firm ground, or equivalent. Ensure
that the ground will not subside, preventing any strain from the attached plumbing.
6. Ensure that there is no movement of the filter during operation of the purge valve.
7. allow sufficient clearance around the filter to permit visual inspection of the entire system.
184.9/700
*nOTE: dE fILTERS REQUIRE a BypaSS
Typical Installation with a Sand filter
Typical installation with a dE filter
MultiCyclone
Typical Installation with a Cartridge filter