Technical data
Switching power pack
Primary
Secondary
Protection type
Protection class
Ambient temperature
Dimensions (L × W × H)
Weight
AquaMax Eco Premium
Connection voltage
Max. current consumption
Max. power consumption
Max. delivery rate
Max. pumping head
Protection type
Max. immersion depth
Suction side
Pressure side
Max. grain size of coarse dirt
Filter inlet area
Water temperature (sub-
merged installation)
Ambient temperature
(dry installation)
Dimensions
Length of connection cable
Weight
34
Mains voltage
Power frequency
Max. power consumption
Cable length
Output voltage
Max. output current
Cable length
Pump
Connection
Thread
Hose connection
Thread
Hose connection
During operation
Outside of operation
During operation and
natural convection
During operation and
forced cooling
Length
Width
Height
100 VA / 12 V DC
V AC
220 ... 240
Hz
50/60
W
110
m
2.0
V DC
12
A
8.5
m
0.5
IP44
II
°C
-10 ... +35
mm
231 × 148 × 68
kg
2.3
6000 / 12 V
V DC
12
A
4.0
W
45
l/h
6000
m
3.2
IP68
IPX4
m
4
G2
mm
25, 32, 38
G2
mm
25, 32, 38, 50
mm
10
cm²
1000
°C
(→ Permissible water values)
°C
-20 ... +35
°C
+4 ... +30
°C
+4 ... +40
mm
340
mm
280
mm
165
m
8
kg
8.7
12000 / 12 V
12
8.5
95
11400
3.2
IP68
IPX4
4
G2
25, 32, 38
G2
25, 32, 38, 50
11
1000
-20 ... +35
+4 ... +30
+4 ... +40
340
280
165
8
10.5