2. INDOOR UNIT INSTALLATION
2.1 INSTALLATION SITE CHOOSING
INDOOR UNIT
■ Where it is out of direct sunlight.
■ Where the airflow is not blocked.
■ Where an optimum air distribution is ensured.
■ Where the condensate can drain correctly and safely.
■ Install the indoor unit on a wall/ceiling that prevents vibration and is strong enough to hold the product
weight.
■ Maintain sufficient clearance around the indoor unit for maintenance and servicing.
■ Where the air filter can be removed and cleaned easily.
■ Where the piping between the indoor and outdoor units is within the allowable limits.
■ Install the indoor unit 1m or more away from the TV or radio to prevent the screen from being distorted or
noise from being generated.
■ Install the indoor unit as far away as possible from fluorescent and incandescent lights so that the remote
control can be operated well.
SPACE REQUIREMENT FOR INDOOR UNIT(42QSS009/012DS*)
The size of outline dimension and air outlet opening
The size of air return opening and
The size of descensional ventilation opening
Air filter
Electric control cabinet
Air filter
Outline dimension
MODEL
(QSS_DS)
A
B
C
700
210
635
009/012
All manuals and user guides at all-guides.com
Air outlet opening size Air return opening size Size of mounted hook
D
E
F
G
H
570
790
65
493
35
T
The size of mounted lug
M
I
J
K
L
M
119
595
200
80
740
Unit: mm
Electric control cabinet
P
New air
inlet
N
O
P
T
350
26
20
Φ90
GB-6