Maintenance Instructions - Schumacher Electric XC75 Manual Del Usuario

Ocultar thumbs Ver también para XC75:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

BATTERY SIZE/RATING
SMALL
200 - 315 CCA
CARS/
315 - 550 CCA
TRUCKS
MARINE/DEEP CYCLE
13.

MAINTENANCE INSTRUCTIONS

13.1
After use and before performing maintenance, unplug and disconnect the battery
charger (see sections 6, 7 and 8).
13.2
Use a dry cloth to wipe all battery corrosion and other dirt or oil from the terminals,
cords, and the charger case.
13.3
Ensure that all of the charger components are in place and in good working condition,
for example, the plastic boots on the battery clips.
13.4
Servicing does not require opening the unit, as there are no user-serviceable parts.
13.5
All other servicing should be performed by qualified service personal.
14.
MOVING AND STORAGE INSTRUCTIONS
14.1
Store the charger unplugged, in an upright position. The cord will still conduct electricity
until it is unplugged from the outlet.
14.2
Store inside, in a cool, dry place (unless you're using an on-board Marine Charger).
14.3
Do not store the clips on the handle, clipped together, on or around metal, or clipped to cables.
14.4
If the charger is moved around the shop or transported to another location, take care to
avoid/prevent damage to the cords, clips and charger. Failure to do so could result in
personal injury or property damage.
15.
TROUBLESHOOTING AND FAILURE CODES
Failure Codes
FAILURE
CODE
The battery voltage is still
under 10V (for a 12V battery)
F01
or 5V (for a 6V battery) after
2 hours of charging.
The charger cannot
F02
desulfate the battery.
The battery was unable
F03
to reach the "full charged"
voltage.
Motorcycle,
6 - 12 AH
garden,
12 - 32 AH
tractor, etc.
40 - 60 RC
60 - 85 RC
550 - 1000
80 - 190
CCA
80 RC
140 RC
160 RC
180 RC
DESCRIPTION
XC103
CHARGE RATE/CHARGING TIME
3 AMP
1¼ - 2½ hrs
2½ - 6¾ hrs
7½ - 9½ hrs
9½ - 12¼ hrs
12¼ - 23¼ hrs
RC
11¾ hrs
18 hrs
20 hrs
22 hrs
Could be caused by trying to charge a 6
volt battery on the 12 volt setting, or the
battery could be bad; have it checked or
replaced.
The battery could not be desulfated;
have it checked or replaced.
Could be caused by trying to charge a
large battery or bank of batteries on too
low of a current setting, or the battery
may have a shorted cell. Try again with
a higher current setting, or have the
battery checked or replaced.
9
5 AMP
12 - 30
AMP
¾ - 1½ hrs
1½ - 4 hrs
45 min - 2½
4½ - 5¾ hrs
1 - 3 hrs
5¾ - 7½ hrs
1¼ - 5 ¾
7½ - 14 hrs
1¼ - 3 hrs
7 hrs
1¾ - 4½ hrs
10¾ hrs
2 - 5 hrs
12 hrs
2¼ - 5½ hrs
13¼ hrs
CAUSE
NR
NR
hrs
hrs
Tabla de contenido
loading

Este manual también es adecuado para:

Xc103

Tabla de contenido