Enlaces rápidos

Owner's Manual
Read Rules for Safe Operation and Instructions Carefully
Working in vicinity of a lead-acid battery is dangerous. Batteries generate explosive gases during normal
battery operation. For this reason, it is of utmost importance that each time before using your charger, you
read this manual and follow the instructions exactly.
WARNING: Handling the cord on this product or cords associated with accessories sold with this product, will expose you to lead, a
chemical known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.
A.
1.
Before you use your battery charger, be sure to read all
instructions and cautions printed on:
• Battery Charger
• Battery
• Vehicle or unit using battery
2.
Use battery charger on LEAD ACID type rechargeable
batteries only, such as used in autos, trucks, tractors,
airplanes, vans, RV's, trolling motors, etc. Charger is not
intended to supply power to low-voltage electrical system
other than in an automotive application.
WARNING: Do not use battery charger for charging dry-
cell batteries that are commonly used with home appliances.
These batteries may burst and cause injury to persons and
damage to property.
3.
Use only attachments recommended or sold by
manufacturer. Use of non-recommended attachments may
result in fire, electric shock, or injury.
4.
When disconnecting the battery charger, pull by the plug
not by the cord. Pulling on the cord may cause damage to
cord or plug.
5.
Locate battery power cord so it cannot be stepped on,
tripped over, or subjected to damage or stress.
6.
Do not operate charger with damaged cord or plug. Have
cord replaced immediately.
7.
Do not operate charger if it has received a sharp blow,
been dropped, or otherwise damaged in any way. Take it to
a qualified professional for inspection and repair.
8.
Do not disassemble charger. Take it to a qualified
professional when service or repair is required. Incorrect
reassembly may result in electric shock or fire.
9.
To reduce risk of electric shock, unplug charger from outlet
before attempting any maintenance or cleaning.
Important Safety Instructions
GENERAL BATTERY SAFETY
SCHUMACHER ELECTRIC CORPORATION
801 BUSINESS CENTER DRIVE • MOUNT PROSPECT, ILLINOIS 60056-2179
Send Warranty Product Repairs to: 1025 E. Thompson, Hoopeston, IL 60942-0280
Call Customer Service if you have questions: 1-800-621-5485
Battery
Charger
Model:
–Save–
10. Do not use an extension cord unless absolutely necessary.
Use of an improper extension cord could result in fire or
electric shock. If an extension cord must be used, make
sure that:
• Pins on plug of extension cord are the same number,
size, and shape as those of the plug on the charger.
• Extension cord is properly wired and in good electrical
condition.
• Wire size is large enough for AC ampere rating of charger,
as specified below:
Length of cord (feet):
AWG size of cord:
(American Wire Gauge)
11. Always charge battery in a well ventilated area.
NEVER operate in a closed-in or restricted area without
adequate ventilation because of risk of explosive gases.
WARNING: Risk of explosive gas.
12. Locate charger as far away from battery as DC charger
cables permit.
13. Do not expose charger to rain or snow.
14. NEVER charge a frozen battery. If battery fluid (electrolyte)
is frozen, bring into a warm area to thaw before charging.
15. NEVER allow battery acid to drip on charger when reading
specific gravity or filling battery.
16. NEVER set a battery on top of charger.
17. NEVER place charger directly above battery being charged.
Gases from battery will corrode and damage charger.
18. NEVER touch the battery clips together when the charger
is energized.
1
SE-4220 Manual Battery Charger
2 Amp, 12V; 10 Amp, 12V
40 Amp, 6 & 12V
200 Amp, 12V, Engine Start
100 Amp, 6V, Engine Start
25
50
16
12
100
150
10
8
00-99-000-414/0204
loading

Resumen de contenidos para Schumacher Electric SE-4220

  • Página 1 SE-4220 Manual Battery Charger Battery 2 Amp, 12V; 10 Amp, 12V Charger 40 Amp, 6 & 12V Model: 200 Amp, 12V, Engine Start Owner's Manual 100 Amp, 6V, Engine Start –Save– Important Safety Instructions Read Rules for Safe Operation and Instructions Carefully Working in vicinity of a lead-acid battery is dangerous.
  • Página 2 PERSONAL PRECAUTIONS AND SAFETY WARNING: Wear complete eye protection and clothing necklaces, and watches when working with a lead-acid protection, when working with lead-acid batteries. battery. A lead-acid battery can produce a short-circuit Make sure someone is within range of your voice or close current high enough to weld a ring (or the like) to metal, enough to come to your aid when you work with or near a causing a severe burn.
  • Página 3 OPERATING INSTRUCTIONS: CHARGING BATTERY IN VEHICLE When charging battery in the vehicle, take care to determine the battery type and which post is grounded. To reduce risk of a spark near battery, follow these steps when battery is installed in vehicle. WARNING: A spark near battery may cause battery explosion. WARNING: Do not connect clip to carburetor, fuel lines, or sheet- Position AC power cord and DC charging cords to reduce metal body parts.
  • Página 4 OUTPUT SELECTOR CONTROLS CHARGE TIME/MINUTES VOLT/RATE SELECTOR 12 VOLT/10 AMP 12 VOLT 40 AMP 12 VOLT 2 AMP Ammeter 12 VOLT 6 VOLT 200 AMP 40 AMP START 100 AMP START TIMER: The main function of the timer is to prevent over charg- AMMETER: The Ammeter indicates the amount of current mea- ing while allowing a battery time to obtain a satisfactory charge.
  • Página 5 ENGINE START Set charge rate switch and timer to OFF positions. If the engine fails to start, charge the battery for 5 more With the charger unplugged from the AC outlet, connect minutes before attempting to crank the engine again. the charger to the battery following instructions given in After the engine starts, move the charge rate switch to OFF section F.
  • Página 6: Troubleshooting

    WARRANTY TO THE ORIGINAL PURCHASER AT RETAIL OF THIS PRODUCT. THIS LIMITED WARRANTY IS NOT TRANSFERABLE. Schumacher Electric Corporation warrants this battery charger for 3 years, and the transformer and rectifiers for 5 years from date of purchase at retail against defective material or workmanship.
  • Página 7 A. SEGURIDAD GENERAL DE ACUMULADORES acumulador de ácido de plomo puede producir un cortocircuito suficientemente fuerte para soldar un anillo (u otro objeto) a otro metal, Antes de usar su cargador de acumuladores, lea todas las instrucciones causando así una quemada severa. y precauciones impresas en: Tenga cuidado de no dejar caer una herramienta u otro objeto metálico •...
  • Página 8: Garantia

    Cuando el acumulador está completamente cargado, desenchufe el Schumacher Electric Corporation garantiza este cargador de batería cargador de la toma de corriente alterna. por tres años a partir de la compra minorista por material o mano de Quite las pinzas en el siguiente orden: (1) del chasis y (2) del terminal obra defectuosos.