Installation
Thermostat
The thermostatic mixing valve must be installed in a
position that is easily accessible for commissioning
and future servicing.
1. When the iBox fitted and the surface tiled, cut
back the plastic rim to within 2mm of the tiles
(fig. 1)
2. Unscrew the allen bolt and remove the flushing
plate. Seal the gap between the plastic box and
the tiles (fig. 2)
3. Fit the the thermostat cartridge into the iBox
using 4 allen bolts. Ensure the hot (red mark)
is on the left and the cold (blue mark) is on the
right (fig.3).
8
1
2
3