Installation

Ice Machine Location

The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met, select
another location.
• The ice machine may be built into a cabinet, however
the location must allow removal of the ice machine for
maintenance. Service diagnostics are performed from the
top of the ice machine. Refer to "Minimum Cut-Out For
Built-In Installations" on page 9.
• The location must be free of airborne and other
contaminants.
• The air temperature must be at least 50°F (10°C), but
must not exceed 110°F (43°C).
• The location must not be near heat-generating
equipment.
• The location must not obstruct air flow through the
condenser (airflow is in and out the front of the ice
machine).
• The location must allow enough clearance for water,
drain and electrical connections at the rear of the ice
machine.
• The ice machine may be installed outside.
The ice machine must be protected if it will be subjected
to ambient temperatures below 32°F (0°C). Component
failure caused by exposure to freezing temperatures is
not covered by the warranty.

Clearances

Top/Sides
Back
Front
*The ice machine may be built into a cabinet. There is no minimum
clearance requirement for the top or sides of the ice machine. The listed
values are recommended for efficient operation and servicing only.
10
Caution
5" (12.7 cm)*
5" (12.7 cm)
24" (60.9 cm)

Leveling the Ice machine

1. Adjust the levelers close to desired height.
2. Move the bin into its final position.
3. Level the ice machine to assure that the bin door closes
and seals properly. Use a level on top of the bin. Turn the
base of each foot as necessary to level the bin.

Leg Option

1. Remove the leg levelers from the bottom of the ice
machine.
2. Screw the legs into the bottom of the ice machine.
3. Screw the foot of each leg in as far as possible.
4. Move the ice machine to its final position.
5. Level the ice machine to assure that the bin door closes
and seals properly. Use a level on top of the bin. Turn the
base of each foot as necessary to level the bin.