TECHNICAL DATA

Dimensions
Beam combiner module (length × width × height) .............................................. 80 mm x 35 mm x 8 mm
Sensor module (width x height x depth) ......................................................... 90 mm x 85 mm x 150 mm
Focus Controller.2 (width x height x depth) ................................................ 250 mm x 105 mm x 220 mm
....................................................................................
Weight
Beam combiner module ...................................................................................................... approx. 45 g
Sensor module ............................................................................................................... approx. 0.70 kg
Focus Controller.2 .......................................................................................................... approx. 3.75 kg
Ambient conditions
Transport (in packaging):
Permissible ambient temperature ................................................................................ -40°C to +70°C
Storage:
Permissible ambient temperature .............................................................................. +5 °C to +40 °C
Permissible relative air humidity (no condensation) ................................................ max. 75 % at 35 °C
Operation:
Permissible ambient temperature .............................................................................. +5 °C to +40 °C
Permissible relative air humidity (no condensation) ................................................ max. 75 % at 35 °C
Altitude of operating site ................................................................................................ max. 2000 m
Atmospheric pressure ......................................................................................... 800 hPa to 1060 hPa
Degree of pollution .......................................................................................................................... 2
Operating data
Definite Focus.2 ................................................................ Free group conforming to DIN EN 62471:2009
Focus Controller.2
Type of operating site ............................................................................................. closed room facilities
Protection class ..................................................................................................................................... I
Ingress protection rate ................................................................................................................... IP 20
Electrical safety ....................................................................................to DIN EN 61010-1 (IEC 61010-1)
Overvoltage category ............................................................................................................................ II
Radio interference suppression .................................................................................. to EN 55011 class B
Noise immunity ......................................................................................................... to DIN EN 61326-1
Line input voltage .................................................................................... 100 VAC to 240 VAC (±10 %)
.......................................................................................................
Line frequency .......................................................................................................................... 50/60 Hz
Power consumption of controller module .............................................................................. max. 2.0 A
6
TECHNICAL DATA
Width including beam path attachment: 115 mm
424533-6044-008
conforming to CSA and UL requirements
No line voltage conversion required!