92001i-EU 1900W RATED PORTAbLE INvERTER GENERATOR
Long Term Storage (more than 1 year)
For storage over 1 year, the gasoline tank and carburetor must
be completely drained of gasoline.
1. Be sure all appliances are disconnected from generator.
2. Place inverter on blocks to allow appropriate gasoline
container or pan to slide under inverter.
3. Remove the maintenance cover.
4. Turn the fuel dial clockwise to the full "RUN" position.
5. Using a Phillips screwdriver, rotate drain screw
counterclockwise (3) full turns. Gasoline will drain through
clear tubing out underneath the inverter. Make sure
draining gasoline empties into an appropriate container.
6. When gasoline stops flowing from the clear tube, rotate
drain screw clockwise until tight. Properly dispose of
the drained gasoline according to local regulations or
guidelines.
7. Turn the fuel dial to the "STOP" position.
8. Follow steps 8-12 according to Short Term Storage.
Transportation
To prevent fuel spillage when transporting or during temporary
storage, the washer should be secured upright in its normal
operating position, with the engine switch OFF. The fuel valve
lever should be turned OFF.
When transporting:
Do not overfill the tank. Do not operate the washer while
it is on vehicle. Take the washer off the vehicle and use
it in a well-ventilated place. Avoid a place exposed to
direct sunlight when putting the washer on a vehicle.1f the
washer is left in an enclosed vehicle for many hours, high
temperature inside the vehicle could cause fuel to vaporize
resulting in a possible explosion. Do not drive on a rough
road for an extended period with the washer on board. If
you must transport the washer on a rough road, drain the
fuel from the washer beforehand.
WARNING
Removing from Storage
If the generator has been improperly stored for a long period
of time with gasoline in the gasoline tank and/or carburetor, all
fuel must be drained and the carburetor must be thoroughly
cleaned. This process involves technically advanced tasks.
For assistance please call our Technical Support Team at
+44 (0)1942 715 407.
If the gasoline tank and carburetor were properly emptied of all
gasoline prior to the generator being stored, follow the below
steps when removing from storage.
1. Be sure the fuel dial is in the "STOP" position.
2. Add gasoline to the generator according to Add Fuel.
3. Move the fuel dial to the "RUN" position.
4. After 5 minutes check the carburetor and air filter areas for
any leaking gasoline. If any leaks are found, the carburetor
will need to be disassembled and cleaned or replaced. If no
gasoline leaks are found, turn the fuel dial to the "STOP"
position.
5. Check engine oil level and add clean, fresh oil if needed.
See Oil Specifications for proper oil type.
6. Check and clear air filter of any obstructions such as bugs
or cobwebs. If necessary, clean air filter according to
Cleaning the Air Filter.
7. Start the generator according to Starting the Engine.
Generator exhaust contains odorless and colorless carbon
monoxide gas.
To avoid accidental or unintended ignition of your generator
during periods of storage, the following precautions should
be followed:
– When storing the generator make sure the fuel dial is set
to the "STOP" position.