All manuals and user guides at all-guides.com
28 | English
Cause
Target surface reflection not distinct (e.g.
water, glass).
Laser beam output (13) and/or reception
lens (12) are covered.
Measurement result implausible
An incorrect reference level has been set.
Obstruction in the path of the laser beam.
The measuring tool monitors for correct operation in every measure-
ment. If a defect is detected, the display will indicate only the symbol
shown opposite. In this case, or if you are unable to rectify an error us-
ing the corrective measures above, send the measuring tool to Bosch
customer service via your dealer.
Checking the accuracy of the measuring tool
You can check the accuracy of the measuring tool as follows:
– Choose a measuring section of approx. 3–10 m in length that is permanently un-
changed, the exact length of which is known to you (e.g. room width, door opening).
The measuring section must be indoors, and the target surface of the measurement
must be smooth and reflect well.
– Measure the section ten times in succession.
The deviation between the individual measurements and the mean value must not ex-
ceed ±2 mm. Record the measurements in order to be able to compare the accuracy
later on.
Maintenance and Servicing
Maintenance and Cleaning
Only store and transport the measuring tool in the protective bag provided.
Keep the measuring tool clean at all times.
Never immerse the measuring tool in water or other liquids.
Wipe off any dirt using a damp, soft cloth. Do not use any detergents or solvents.
Take particular care of the reception lens (12), which must be handled with the same
level of care you would give to a pair of glasses or a camera lens.
1 609 92A 4PE | (25.10.2018)
Remedy
Cover the target surface
Keep the laser beam output (13) and/or re-
ception lens (12) clear
Select a reference level that is appropriate
for the measurement
The laser point must be fully on the target
surface.
Bosch Power Tools