Supply Cable Status Check; Thorough Cleaning Of The Grinders; Storing The Grinder; When Necessary - Fiorenzato All Ground Manual De Instalación, Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

EN
6.1.2

Supply cable status check

AFTER EACH USE:
With the cable disconnected from the power outlet, visually check, as well as checking with
your hands, that the plug and protective sheath are not damaged and that the wires are not
exposed.
ATTENTION! If damage is found to the power cord, have it replaced by a specialist
repair service.
6.1.3

Thorough cleaning of the grinders

EVERY 6 MONTHS:
The grinders must be thoroughly cleaned at least every 6 months (or sooner if deemed
necessary), using products specifically designed to clean grinders, which are easily available
on the market (e.g. PULY GRIND detergent for coffee grinders).
Thorough cleaning must be done once normal cleaning has been completed, with the
machine emptied of coffee and without the supply hopper.
Clean the grinders by pouring a dose of product into the grinding chamber (completely
empty) and then starting the grinding cycles until the product is completely ground. During
grinding, the product (in grains or crystals) regenerates the grinders, completely removing
any coffee deposits, encrustations, moulds and fatty deposits from their surfaces, absorbing
the oil and destroying any rancid part without leaving residues.
In this way, the grinders are regenerated without the need to disassemble them.
6.1.4

Storing the grinder

If the grinder is not going to be used for a long period, it is advisable to carry out the following
operations to keep it in good condition and to avoid any issues the next time it is restarted.

WHEN NECESSARY:

Carefully clean the grinder as described in Para. 6.1.1.
Thoroughly clean the grinders as reported in Para. 6.1.3.
Unplug the power cord from the power outlet.
Cover the machine with a cloth to protect it from dust and dirt.

6.2 Extraordinary maintenance

No extraordinary maintenance operations are envisaged for the grinder. However, if there are any
breakages and/or malfunctions not covered in the section "7 ANOMALIES - CAUSES - REMEDIES",
do not intervene on the device on your own initiative but entrust the search for and resolution of the
fault to a specialist technician. Contact the assistance service of Fiorenzato M.C. S.r.l.
48 / 102
check the power cable. (Fig. 32)
clean the grinders thoroughly (Fig. 33)
when setting the machine aside for a long period (Fig. 34)
Fiorenzato | Cod. AllGround_001 Ed. 01/2021