2.7
List of parameters (Technical parameters)
Viewing of screen
TECHNICAL
Enabling of 2nd pellet container
External thermostat
Viewing on display h
o
2
110V / 60Hz
IGNITION
Pellet pre-loading (s)
Compressed air (s)
Initial ventilation
Minimum lux start-up
Lux shut-down
Dead band (s)
Flame stabilisation (m)
POWER LEVELS
Type
Fuel supply interval.
Start-up
Fan
Power 1
Fan
Power 2
Fan
Power 3
Fan
Power 4
Fan
Power 5
Fan
NOTA
CLEANING
Cleaning intervals (m)
Grill cleaning (s)
Fan cleaning
Compressed air
External fan
Shutting down
Duration
Ventilation
External thermostat.
36
Description
Hysteresis for water regulation temperature. When the set tem-
hysteresis value programmed falls below the set value, the burner
starts up again.
Maximum value the water temperature can reach beyond the
set value. If the temperature exceeds the set value of the amount
temperature programmed in the temperature control parameter is
reached "∆ temperature ceck".
Enables the use of 2nd pellet container.
Enables the use of an external thermostat (e.g. TA or TB).
Enables viewing on the screen of the temperature programmed for
the water in the boiler.
To be activated in the countries with this mains voltage.
Duration of cleaning process with compressed air.
Fan intensity in the ingnition phase after the "pellet pre-loading"
phase ("precarico pellet").
Minimum brightness to establish a regular ignition.
If the brightness goes below the level recorded during the time reg-
ulated within the Dead Band parameter ("Banda Morta"), the burner
shuts down. If this happens during normal running of the appliance,
the signal ERROR appears on the display.
This is the time during which the optical sensor must continuously
record a value higher than the parameter "Minimum lux start- up"
("Lux minimo avvio"). Every time the values recorded go below the
parameter Minimum lux start- up ("Lux minimo avvio"), the count
starts up again.
burner is enabled to start up.
Type of combustion being used.
Time between one pellet reloading and the next.
Filling Time from external cochlea to start.
Fan speed at start.
Filling Time from external cochlea to Power 1.
Fan speed at Power 1.
Filling Time from external cochlea to Power 2.
Fan speed at Power 2.
Filling Time from external cochlea to Power 3.
Fan speed at Power 3.
Filling Time from external cochlea to Power 4.
Fan speed at Power 4.
Filling Time from external cochlea to Power 5.
Fan speed at Power 5.
The interval between the cleaning of the combustion grill carried
out by the burner fan and the cleaning carried out with compressed
air.
Duration of cleaning process with burner fan running at maximum
power.
Fan speed during cleaning phase.
Presence of compressed air kit (optional).
Speed of cochlea fan.
The time during which the ventilator goes on running at max. power
objective is to burn all the residual fuel left on the grill. This cycle is
Fan speed during shut-down phase.
This determines the operational mode of the burner once the envi-
ronment set value programmed has been reached.
Factory default
U/M
Field
setting
°C
2 ÷ 30
°C
1 ÷ 5
YES / NO
sec
0.0 ÷ 60.0
sec
0.0 ÷ 20.0
rpm
0 ÷ 300
Lux
0 ÷ 1000
Lux
0 ÷ 100
sec
0 ÷ 600
min
0 ÷ 20
A-B-C-D
Sec.
1.0 ÷ 90.0
Sec
0.0 ÷ 30.0
rpm
0 ÷ 300
Sec
0.0 ÷ 60.0
rpm
0 ÷ 300
Sec
0.0 ÷ 60.0
rpm
0 ÷ 300
Sec
0.0 ÷ 60.0
rpm
0 ÷ 300
Sec
0.0 ÷ 60.0
rpm
0 ÷ 300
Sec
0.0 ÷ 60.0
rpm
0 ÷ 300
min
0 ÷ 300
sec
1 ÷ 180
rpm
0 ÷ 300
YES / NO
rpm
0 ÷ 300
min
0 ÷ 20
rpm
0 ÷ 300
min
0 ÷ 90
2
5
On
NO
10
6,00
160
60
20
60
1
A
45.0
3,0
220
2,0
150
3,5
160
4,5
170
5,5
180
6,5
200
60
30
300
NO
300
2
300
0