AXIS Ex Series
2. Remove the back cover. Carefully pull the back cover off.
3. Route the cables through threaded entry points and suitably certified glands.
CAUTION
Take extra care to not damage the joint surface.
WARNING
Earthing connection must be minimum 14 AWG (2 mm²) conductor with green and yellow
insulation. Connect through the M4 earth stud using the supplied crimp ring terminal.
Tighten with a 7 mm ring spanner or socket.
The terminal plugs can be disconnected to allow easy termination outside of the enclosure. For TB1
and TB2 use wire between 18 - 12 AWG / 0.8 - 3.0mm².
WARNING
Only one wire should be connected to each clamping point.
An external earth connection point is available for up to 11 AWG (4 mm²) connection. When used,
it should be used with a crimp ring terminal.
Use an RJ45 connector (CAT5 or higher) for network connection. Optionally, an SFP slot is available
for an additional network connection, this port utilizes various SFP modules including fibre optic.
You can also use the RJ45 network connection to supply power to the housing. When used with
Power over Ethernet (PoE), the Power Sourcing Equipment (PSE) shall comply with IEEE 802.3bt
type 3 Class 6 PoE.
WARNING
The use of a fibre optic cable and internal connections shall comply with requirements
of UL/IEC/EN 60079-14.
When wiring is completed, fit the back cover. Tighten the 6 M5x12 A4 socket head screws to 8 Nm
±0.5 torque. Use the included stainless steel bits.