AXIS Ex Series
Specific conditions of use
WARNING
Always refer to the product certificates for any specific conditions of use.
•
Flameproof joints are not to be modified.
•
Cable temperature can exceed 60 °C. Use a suitable cable for the end application.
•
Cable entries into the equipment shall utilise suitably certified cable glands, thread
adaptors or plugs that shall provide a minimum degree of protection to maintain the
ingress rating of the equipment. As a minimum this should be IP66 or IP67.
•
Unused cable entry apertures shall be closed with suitably certified blanking plugs.
•
The protective guard on the thermal housings must not be removed.
•
Yield strength of the end cap fasteners is A4-80.
•
For coal mining applications, equipment shall only be installed where it has been
assessed that there is a low risk of mechanical damage from impacts which could
compromise the enclosure's flameproof protection.