Fein Slugger JCM 200 QX Instrucciones De Uso página 7

Ocultar thumbs Ver también para Slugger JCM 200 QX:
Idiomas disponibles

Idiomas disponibles

Extension cable.
If the use of an extension
WARNING
cord is required, its length
and conductor cross-section must be ade-
quate for the application in order to prevent
a voltage drop in the extension cord, power
loss and overheating of the power tool. Oth-
erwise, the extension cable and power tool
are prone to electrical danger, and the
working efficiency is decreased.
Intended use of the power tool:
Magnetic core drill unit for drilling with core
drill bits and solid drill bits, reaming, coun-
tersinking and tapping on materials with sur-
faces suitable for magnets in weather-
protected environments using the applica-
tion tools and accessories recommended by
Slugger.
Operation of the power tool off power generators.
This power tool is also suitable for use
with AC generators with sufficient
power output that correspond to the Stan-
dard ISO 8528, design type G2. This Stan-
dard is particularly not complied with when
the so-called distortion factor exceeds
10 %. When in doubt, please refer to the
generator instruction/specification guide.
Recommended dimensions of extension
cords at an operating voltage of 120 V – sin-
gle-phase a. c., with only JCM 200 QX, JCM
200 U, JCM 200 auto, JCM 256 U connected:
Max. cable length, ft Max. cable length, m
100
200
100
–200
–300
Min. conductor size
A.W.G.
16
14
Operating the power tool off
WARNING
power generators whose no-
load speed exceeds the voltage value on the
type plate of the power tool is prohibited.
en
≤ 30
30
–60
Min. conductor-
cross-section, mm
12
1.5
2.5
7
60
–100
2
4
loading

Este manual también es adecuado para:

Slugger jcm 200 uSlugger jcm 200 autoSlugger jcm 256 u