Fein Slugger JCM 200 QX Instrucciones De Uso página 14

Ocultar thumbs Ver también para Slugger JCM 200 QX:
Idiomas disponibles

Idiomas disponibles

en
14
Filling the coolant container.
Prevent the flow of liquid along the cable into the socket outlet or into the
WARNING
core drill unit, as this can lead to electric shock. Tie a bow in the cable near
the plug, so that any liquid can drip off.
Do not use the magnetic core drill unit when the coolant-lubricant system is defective. Each
time before operating, check for tightness against leaks and for cracks in the hoses. Prevent
liquids from entering or penetrating electrical components.
Filling the mounted coolant container
(figure 5)
Unscrew the cap from the coolant con-
tainer.
Fill in pump-feedable cooling lubricant, e.g.
Slugger cutting oil.
Screw the cap onto the coolant container
again.
Filling the dismounted coolant container
(figure 6)
Pull the empty coolant container out of the
drill stand housing of the magnetic core drill.
Unscrew the cap from the coolant con-
tainer.
Fill in pump-feedable cooling lubricant, e.g.
Slugger cutting oil.
Screw the cap onto the coolant container
again.
Insert the filled coolant container into the
holder on the drill stand housing intended
for this purpose.
Upper closing cap
Coolant container
Upper closing cap
Coolant container
loading

Este manual también es adecuado para:

Slugger jcm 200 uSlugger jcm 200 autoSlugger jcm 256 u