Working instructions.
When there is danger of falling down, secure the machine using the provided
WARNING
safety strap; especially when working aloft, on vertical building elements or
overhead. In case of a power failure or when the mains plug is pulled, the magnetic holding
power is not maintained.
Fastening the safety strap (figure 9).
Always fasten the machine securely around
the workpiece using the provided safety
strap.
For switching the magnet ON
(figure 10).
Please make sure that the contact sur-
facefor the magnetic base is level, clean
and rust-free. Remove any varnish or
primer.
When working, always use the magnetic
foot; pay attention that the magnetic holding
power is sufficient:
Press the Magnet button to start the
machine.
– When the green Magnet button on the
control panel lights up permanently, the
magnetic holding power is sufficient and
the power tool can be operated with
manual or automatic feed.
– When the Magnet button on the control
panel flashes green, the magnetic holding
power possibly is insufficient and the
power tool must be operated manually
with reduced feed. In this case, the JCM
200 auto may not be operated in auto-
matic mode.
When working on non-metal materials,
suitable clamping devices, such as the vac-
uum plate or pipe-drilling fixture, which are
available as accessories, must be used.
When working on steel materials with a
material thickness less than 12 mm, the
workpiece must be enforced with an addi-
tional steel plate in order to ensure the mag-
netic holding power.
The magnetic foot is monitored by means of
a power sensor. If the magnetic foot is
defective, the drill motor will not start.
JCM 200 QX, JCM 200 U, JCM 256 U
Switches the magnet On/Off
JCM 200 auto
en
Clamping strap
=
=
17