DISPLAYING
Err5
The display shows
Err7
The display shows
Err8
The display shows
Err9
The display shows
Er10
The display shows
Er13
The display shows
Er14
The display shows
DESCRIPTION
When a start command is given the gate
won't open.
It means that the test of the safety edges
failed.
Encoder error
When executing a self-learning function the
control is refused.
It means that the setting of the control
unit is not compatible with the requested
function.
It means that programming was locked by
means of the programming lock key CL1+
(code 161213).
When a start command is given the gate
won't open.
This means that the ADI module function
test failed.
The self-diagnosis circuit has detected
a malfunction that prevents the safe
operation of the automation
The self-diagnosis circuit has detected an
error in the configuration parameter table
SOLUTION
1. Make sure that the menu relative to the test of the
facets for cables (
2. Make sure that the safety edges enabled by menu are
actually installed.
Check the connection of the encoder
1. Check the Start inputs are enabled in standard mode
Strt
(
menu set on
2. Check the ADI interface is disabled
i.Adi
(
menu set to
To change the settings it is necessary to insert in the
connector of the ADI interface the same key used to
activate the programming lock, and unlock the device.
1. Check the ADI module is correctly inserted
2. Check the ADI module is not damaged and working
properly
Contact the V2 technical assistance service to send the
control unit for repair
Enter the configuration menu, carefully check all the
parameters and correct any errors. If the error persists,
contact the V2 technical assistance service to send the
control unit for repair
- 56 -
Co.tE
) is configured correctly.
StAn
).
no
).