4.6 - Memorizing the FIRST transmitter permane
WARNINGS
• A transmitter can be memorized as a first transmitter only if no other transmitter is memorized in the motor, or only the utility transmitter is memorized.
• DO NOT use this procedure to memorize the second (or third, fourth, etc.) transmitter: use procedure 4.10.
• This procedure memorizes the transmitter in "Mode 1" ("Mode 1" is explained in paragraph 4.3.3).
1
OFF
2 sec
Disconnect the
wait for 2
restore the
power supply
seconds
supply
Note – After memorization, the raising and lowering direction of the rolling shutter is not yet associated with the s and t keys of the transmitter. Association will take
place automatically during adjustment of the "0" and "1" limit switches; the rolling shutter will move in "hold-to-run" mode until the limit switches are adjusted. After
this, a simple impulse on the control will move it.
4.7 - Guided High ("0") and Low ("1") limit switch recognition
This procedure matches the motor rotation direction with the s and t keys on the control device, so that the s key raises the rolling shutter and the t key lowers it.
Note – When the limit switches are memorized with this procedure, the two heights are controlled and updated constantly by the "limit switch self-update" function
(see paragraph 5.3).
1
2
Initiate
an UPWARD
manoeuvre
Bring the shutter up
Keep the button pressed
for half its stroke
3
Initiate a
DOWNWARD
manoeuvre
Keep the button pressed
Note – After programming, the s key will command the Raise motion and the t key will command the Lower motion. If the result is not as expected, delete the limit
switch heights (procedure 4.11) and repeat the limit switch recognition process.
ON
2
count 2 movements
ATTENTION! – Programming intended exclusively for rolling shutters with mechanical blocks for the limit
switch.
...?...
wait ...
...?...
wait ...
wait for the shutter to be stopped by the anti-
intrusion rigid springs hitting the structure (=
limit switch LOW = dimension "1")
2
= 5 sec
3
Keep both buttons
count 3 movements
pressed at the same
time
"0"
wait for the shutter to be stopped by the
safety stoppers hitting the structure (= limit
switch HIGH = dimension "0")
"1"
release the button
the end
release the buttons
 3
release the button
the end
English – 4