4. Transport _____________________________________________
4.1. Handling
• Carefully transport the unit to the customer's setup location to prevent any damage to the
unit.
• Secure the unit to the pallet to prevent it from sliding.
NOTICE
If the drum is removed, one person can transport the unit to ist setup location.
• When transporting the drum, please follow the safety instructions on the solvent's data
sheet.
4.2. Transport Aids
4.2.1. Transport using a crane
• Attach crane cables to the pallet and carefully raise the unit Pay special attention to the
unit's center of gravity. The unit may tip over!
NOTICE
The crane must have a carrying capacity of at least 200 kg.
4.2.2. Transport using a forklift
• Guide the forklift between the longitudinal braces of the wooden base of the pallet.
• Lift the unit and transport it.
5. Setup / Startup ________________________________________
5.1. Securing the Unit / Stability
The unit must be placed in a level and stable location on a solvent-resistant floor .
5.2. Space Required
The unit may be placed in front of a wall. There should be approx. 1.5 metres of free space in
front of the unit.
5.3. Acceptable Ambient Conditions
The unit will work optimally at temperatures between +10° and +30°C.
5.4. Connection Conditions
A professional electrician must perform the installation of electrical supplies for the
customer.
DANGER
The electrical supply line is to be installed in accordance with all regulations and the information
(technical data) in the instruction manual.
Operating Instructions Parts Cleaner Type F/F2 (02/2010/EN)