NOTE
The unit will be destroyed if water penetrates the plug connector.
• Connect the plug connector or place the protective cap on the plug connector.
– Ensure that the rubber seal is clean and fits precisely. If the rubber seal is damaged, replace
it.
– Secure the plug connector or protective cap with the two screws.
Submerged installation of the unit
Connection
B
Do not plug the power plug into the outlet yet!
Installation
C
• Position the pump horizontally on a firm, mud-free surface.
• Ensure that the pump is securely positioned.
• Only operate the pump when it is fully submerged.
A pull rope allows you to simply pull the pump out of the water.
− Pull the pull rope through the round openings on the bottom pan of the filter and make a
knot.
Connecting the switching power pack to the pump
NOTE
If water penetrates the plug connectors, this will destroy the pump.
Never undo the union nuts on the plug connectors.
• The stud on the plug connector of the pump must engage with the plug connector of the
switching power pack.
Do not plug the power plug into the outlet yet!
Once the plug connectors of the filter pump and switching power pack have been inserted and
have engaged, they can only be disconnected by means of a screw driver.
AMX0077
EN
AMX0077
15