HDT0W00x HD6 Weather Dome Quick Installation Guide
WARNING: Installation must be performed by qualified technical
personnel and must be in accordance with all national and local
mechanical and electrical codes.
Perform the following steps to install a HD6 weather dome on a Honeywell Video Systems outdoor mount with an
ELL conduit fitting or an MDW1210W mount.
1. Select the location(s) of the housing (s). Each HD6 requires a 24Vac ± 10% power source measured at the
dome. Ensure a 24Vac @ 1.1A power source is available. An additional 24Vac @ 4A power source is required
for the heater/blower installed in the weather dome.
2. Install the mount using the instructions provided with your specific mount. Run the required field wiring and
safety cable through the mount for the HD6 weather dome. The field wiring and safety cable are the
responsibility of the installer. Honeywell Video Systems recommends using 3/32" plastic coated aircraft cable,
part number 849518-0311, for the safety cable and looping sleeves, part number 849511-0057.
NOTE: Only the weather or pressurized domes with No Connector is compatible
with the MDW1210W mount.
3. Refer to Figure 1 for standard wiring.
Refer to Figure 2 for Unshielded Twisted Pair (UTP) wiring.
4. Locate the 1-1/2" NPT conduit nut shipped loose with the mount.
Thread the conduit nut onto the black threaded nipple on the weather dome with the teeth on the nut away from
the dome.
5. Wrap Teflon tape (installer supplied) around the black threaded nipple
on the weather dome.
6. Attach the safety cable (as shown in the figure to the right) from the
building structure to the weather dome. Use a looping sleeve, (part
number 849511-0057) (not supplied) to secure the safety cable. Route
the safety cable through one side of the looping sleeve, around the pin
in the weather dome, and through the other side of the looping sleeve.
Secure the safety cable by crimping the looping sleeve.
Rev. 1.01
7. Install the weather dome on the mount. Carefully push the cabling from the weather dome up into the mount
and thread the weather dome into the threaded pipe on the mount.
8. After the weather dome is threaded into the mount as far as it will go, thread the conduit nut on the weather
dome up against the mount and tighten. Seal the joint between the mount and the black nipple on the weather
dome with Dow RTV 3145.
9. Connect mating connector J2 (field wiring) in the mount to connector P2 on the weather dome (on 14-pin
connector version only.)
10. Replace the cover on the mount conduit box or access hole cover plate on the MDW1210W mount using the two
screws removed when installing the mount.
SAFETY CABLE INSTALLATION
(SUPPLIED BY INSTALLER)
11. Seal all joints and screws in the outdoor mount. Use Dow 3145 RTV for Allen head screws, bolts, joints, and all
ATTACH THE SAFETY CABLE
mounting surfaces. Use Teflon tape for threaded joints.
TO A BUILDING SUPPORT STRUCTURE
SPLICING SLEEVE
SAFETY CABLE
SPLICING SLEEVE
12. Refer to the HD6 Series User Manual to install the scan.
LOOP AROUND PIN IN BLACK
NIPPLE OF WEATHER DOME
1
CAUTION: Do not force the dome into the threaded pipe.
The nipple on the weather dome is plastic and the threads on the
nipple could be stripped if force is used.
CAUTION: Ensure all field wiring is pushed back into the mount
pipe. Ensure the gasket between the conduit box or mount and
the cover is seated properly.
CAUTION: All joints, bolts, and screws in the mount must be
sealed to prevent water (moisture) from entering the weather
dome.
900.0812