Figure 1 Standard Wiring – 14-Pin Connector and No Connector (Fly-Leads)
CAUTION: VERIFY THE TYPE OF CONNECTOR (14-PIN OR NONE) PRIOR TO
CONNECTING WIRING OR EQUIPMENT DAMAGE MAY OCCUR.
HD6 WEATHER DOME
MATING CONNECTOR (J2) - 14 PIN
DOME MATING CONNECTOR (J2)
2 CONDUCTOR DATA (RX) CABLE
24" (609.6) LG PIGTAIL
(BLACK & CLEAR)
2 #18 AWG WIRES FOR POWER
24" (609.6) LG PIGTAIL
(BLACK & WHITE)
2 #18 AWG WIRES FOR 24VAC HEATER/BLOWER
BNC MALE CONNECTOR
24" (609.6) LG PIGTAIL
AND 6" (152.0) LG.
(ORANGE & YELLOW)
RG-174/U COAX CABLE
BLACK
24VAC DOME POWER
SEE TABLE 1
WHITE
24VAC DOME POWER
BLACK
DATA RX-
RS-485 RATED CABLE
CLEAR
DATA RX+
BROWN
DATA TX-
RED
DATA TX+
ORANGE
HEATER/BLOWER
24VAC HEATER
YELLOW
WIRING - SEE TABLE 2
24VAC HEATER
GREEN
ALARM 1
BLUE
ALARM 2
RG-59/U COAX
BNC
VIDEO
RUNS LESS
CONNECTOR
THAN 1500 FEET
VIDEO SHIELD
VIOLET
GROUND
GRAY
ALARM COM
TABLE 1
HD6 POWER REQUIREMENTS: 24VAC
±10%
HEATER/BLOWER POWER REQUIREMENTS: 24VAC @ 4A
24 VAC POWER @1.1A
AWG
MAX. DISTANCE TO DOME
22
65 FEET (19 METERS)
AWG MAX. DISTANCE TO DOME
20
100 FEET (30 METERS)
18
160 FEET (48 METERS)
16
260 FEET (79 METERS)
14
420 FEET (128 METERS)
12
650 FEET (198 METERS)
IF YOU ARE USING A 3M OR 10M EXTENSION CABLE, USE THE WIRING DIAGRAM SUPPLIED
WITH THE EXTENSION CABLE.
Rev 1.01
(H 6 No Connector Shown)
D
DOME WIRING, 13.5 (340) LG., SEE BELOW
THREADED NIPPLE
FEMALE BNC FOR VIDEO
HD6 WEATHER DOME WIRING
NO CONNECTOR
BLACK
24VAC DOME POWER
WHITE
24VAC DOME POWER
BLACK/WHITE
DATA RX-
BLACK/ORANGE
DATA RX+
WHITE/BLACK
DATA OPTION WIRING
DATA TX-
(REQUIRES SPECIAL
WHITE/VIOLET
DATA TX+
FIRMWARE)
BROWN
GROUND
RED
24VAC L1
TO 24VAC
ORANGE
HEATER/BLOWER
NOT USED
ASSEMBLY
YELLOW
24VAC L2
GREEN
ALARM 1 OPTION
BLUE
ALARM 2 OPTION
VIOLET
ALARM 3 OPTION
GRAY
ALARM 4 OPTION
WHITE/BROWN
ALARM 1 OPTION COMMON
WHITE/RED
ALARM 2 OPTION COMMON
WHITE/ORANGE
ALARM 3 OPTION COMMON
WHITE/YELLOW
ALARM 4 OPTION COMMON
VIDEO
BNC
VIDEO
CONNECTOR
VIDEO SHIELD
VIDEO SHIELD
TABLE 2
24VAC HEATER/BLOWER POWER
MAXIMUM WIRE LENGTHS
THERMOSTAT:
ON 70
OFF 9 °F
18
62 FEET (18.9 METERS)
OUTPUT 96W
16
99 FEET (30.2 METERS)
14
158 FEET (48.2 METERS)
12
251 FEET (76.5 METERS)
CAUTION: VERIFY THE TYPE OF CONNECTOR (14-PIN OR NONE) PRIOR TO
INTERFACE BOARD 518753-1030
W1
W2
W4
SW1
Jumper W1
Terminated
Position 1 & 2 Last Dome on Data Loop
Unterminated
Position 2 & 3 All Intermediate Domes on Data Lo op
Jumper W2
Positions 2 & 3 All Domes
Jumpers W3 & W4
UTP
Positions 1 & 2
Not Used
Positions 2 & 3
To use the board as standard (video over coax & 2-wire RS485):
Jumper W3
Positions 1 & 2
Jumper W4
Positions 2 & 3
DIP Switch
SW1
Control & Video Over UTP
UTP Cable
Switch Position
Feet
Meters
1
2
0-300
0-90
Off
Off
300-600
90-180
On
Off
600-900
180-270
Off
On
900-1200
270-365
Off
Off
1200-1500
365-455
Off
Off
* Use lowest switch setting possible.
Ex: If cable run is 900 feet, use 600-900 switch setting.
Make sure only one switch is set to ON.
Note: If an active receiver (e.g., NVT Model NV-652R)
is used at the monitor, set all switches to OFF.
If the compensation is not enough, set SW1-1 to ON.
Ensure all other switches are set to OFF.
TABLE 1
HD6 POWER REQUIREMENTS: 24VAC
24 VAC POWER @1.1A
AWG
MAX. DISTANCE TO DOME
22
65 FEET (19 METERS)
20
100 FEET (30 METERS)
18
160 FEET (48 METERS)
16
260 FEET (79 METERS)
14
420 FEET (128 METERS)
12
650 FEET (198 METERS)
°F
0
IF YOU ARE USING A 3M OR 10M EXTENSION CABLE, USE THE
WIRING DIAGRAM SUPPLIED WITH THE EXTENSION CABLE.
2
www.honeywellvideo.com
Figure 2. UTP Option Wiring – No Connector
CONNECTING WIRING OR EQUIPMENT DAMAGE MAY OCCUR.
DOME WIRING, 13.5 (340) LG., SEE BELOW
FEMALE BNC FOR VIDEO
INTERFACE BOARD
HD6 WEATHER DOME WIRING
UTP OPTION (VIDEO ON UNSHIELDED TWISTED PAIR)
24VAC DOME POWER
24VAC DOME POWER
DATA OPTION
WIRING REQUIRES
SPECIAL FIRMWARE
3
4
Off
Off
TO 24VAC
Off
On
HEATER/B LOWER
Off
Off
ASSEMBLY
On
Off
Off
On
ALARM 1 OPTION COMMON
ALARM 2 OPTION COMMON
TABLE 2
±10%
HEATER/BLOWER POWER REQUIREMENTS: 24VAC @ 4A
24VAC HEATER POWER
MAXIMUM WIRE LENGTHS
THERMOSTAT: ON 70
AWG
MAX. DISTANCE TO DOME
18
62 FEET (18.9 METERS)
16
99 FEET (30.2 METERS)
14
158 FEET (48.2 METERS)
12
251 FEET (76.5 METERS)
THREADED NIPPLE
1.62"
(41.1mm)
9.54"
(242.3mm)
12.29" REF
(312.2mm)
BLACK
WHITE
BLACK/WHITE
DATA RX
-
BLACK/ORANGE
+
DATA RX
WHITE/BLACK
DATA TX
-
WHITE/VIOLET
DATA TX
+
BROWN
GROUND
RED
24VAC L1
ORANGE
NOT USED
YELLOW
24VAC L2
GREEN
ALARM 1 OPTION
BLUE
ALARM 2 OPTION
VIOLET
NOT USED
GRAY
NOT USED
WHITE/BROWN
WHITE/RED
WHITE/ORANGE
VIDEO
+
(CAT5)
WHITE/YELLOW
VIDEO (CAT5)
-
NOT USED
NOT USED
°F
OFF 9 °F
0
OUTPUT 96W
900.0812
10/06
loading