Replacing The Doors - Kenmore 596.57002600 Guía De Uso Y Cuidado

Ocultar thumbs Ver también para 596.57002600:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installation
Door and Hinge Removal
Some installations require door removal to get
refrigerator to final location.
To avoid severe personal injury or death,
observe the following:
• Disconnect power to refrigerator before removing
doors. Connect power only after replacing doors.
• Green ground wire must be attached to top hinge
while performing door removal and replacement.
• Tape decorative panels (select models) securely
into place before removing door handles.
To avoid property damage, observe the following:
• Protect vinyl or other flooring with cardboard, rugs
or other protective material prior to moving
refrigerator.
1. Unplug power cord from power source.
2. Remove toe grille.
• Open both doors 180°, or as wide as possible.
Note:
For refrigerators in operation, shut off water
before removing water line from the door.
To Disconnect the Water Line:
• Push in white collar (A) and hold.
• Pull the door-side tube from the connector (B).
To Reconnect the Water Line:
• Firmly push tube
lines on the tube as a guide for full insertion.
• If tube end is damaged, cut off
reconnecting.
• If leaking occurs, disconnect and reconnect the
line.
8
All manuals and user guides at all-guides.com
WARNING
CAUTION
A
B
" into the connector. Use
5
8
" before
5
8
3. Close doors.
4. Remove top hinge covers by
removing Phillips screws.
5. Unscrew
5
" hex head screws
16
from top hinges.
• Do not remove screw
connecting green ground
wire.
6. Detach main wire connector harness and red wire
harness.
• To detach main wire
harness, use a flat blade
tool or fingernail to press
junction point between two
connectors to release.
• To detach red wire harness,
press tab on underside of
connector to release.
7. Remove top hinges along with doors.
8. Remove bottom hinges with a

Replacing the Doors

To replace the doors, follow the steps in Door and
Hinge Removal in opposite order.
Important: If water line tube end is damaged, cut off
5
" before reconnecting.
8
" hex head driver.
3
8
Tabla de contenido
loading

Tabla de contenido