Urmet Yokis MVR500EBRP 454812 Manual Del Usuario página 9

Mecanismo doble local para accionamiento de persianas para empotrar, 1 módulo
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 11
POWER-UP
Care iS reQUired for shutters with mechanical limit switches: do not power up if the shutter is completely closed.
Position the shutter mid-way using the opening and closing wires before powering up the module.
The module will adapt automatically to the various types of shutters with electronic, electrical, or mechanical limit switches.
Motor operation is always limited to 90 seconds, except in the case of the electronic limit switches: in this case the operation
is limited to 40 seconds. Installers may change this type from 5 seconds (minimum) to infinite by using the electronic limit
switches (contact our Customer Care if necessary). Code 24 disables torque control. Use code 26 if the shutter stroke is
longer than 40 seconds.
OPERATION
1. Use of the module
The MVR500EBRP is controlled by the buttons on the device. The shutter reacts within a few tenths of a second after pressing
the pushbutton.
Press the up pushbutton to open and stop opening. Press the down pushbutton to close and stop closing. While closing,
pressing the up pushbutton will cause a 0.5 second stop before opening. Pressing both pushbuttons at the same time will
open the shutter.
With remote control: Refer to the remote control instruction manual.
Short presses: Yokis modules can be used or configured by means of sequences of short presses. The speed must be at
least two presses per second. The shutter will not move during the press sequence. The shutter will confirm the configuration
with a short up and down movement at the end of the press sequence. If several modules have to be configured identically,
the short press method may be used on the double centralised pushbuttons,–either on the up or down pushbutton.
iMPortaNt: Before performing any configuration, the module must be unlocked by briefly pressing of one of the
two buttons 23 times
2. intermediate position
An Intermediate position can be configured (for example: with the slats open). In order to do this, close the shutter
completely and then open it to the desired Intermediate position. 5 short presses will memorise the position. From this
moment on, 2 short presses will take the shutter to the previously stored position from any current position (closed, open, or
in between).
3. restoring default settings
25 short presses will restore the default settings. The module will perform the following actions in sequence: delete the
electronic limit switches, enable inverted movement in case of overload, set motor torque to low, delete up and down wire
logic reversal, enable limit switch and motor torque control.
To restore the default settings on the module without eliminating the logical reversal of the up and down wires of the
motor, briefly press 27 times
4. How to block the module
The configuration block prevents accidentally changing the module settings in case of repeated presses. The module is not
blocked when it leaves the factory. 21 short presses block the module. The module will no longer respond to configurations
made using the short presses sequence from 12 to 26. An exception is the 23 short presses sequence, which allows to
remove the block. The module will respond again to configurations set using the short presses sequences from 12 to 26.
For modules cod. 5454811 and 5454812, briefly press the area marked "Connect".
DIRECT MODE RADIO CONNECTION
1. Step 1:
5 short presses of the push button to be connected to the transmitter.
The transmitter LED will start flashing for 30 seconds, indicating that the system is waiting for a connection.
2. Step 2
While the transmitter LED is blinking, briefly press the "Connect" area of the receiver (located at the top of the case).
The receiver relay will flash once and the transmitter LED will stop flashing if the connection was successful.
Warning: the receiver must be powered up.
to delete a connection: repeat the procedure above.
Urmet S.p.a. – 10154 toriNo (itaLY) – Via Bologna 188/C
Customer Service: +39 011.23.39.810 - export dept. Phone: +39 011.24.00.250/256
DS1054-065A
For technical information, go to www.yokis.com or call:
P9
Tabla de contenido
loading

Tabla de contenido