D
C
B
I
LED F Hold.
May not be selected. Activated in MIG and MMA
welding, signals that the values shown on displays M
and N (normally Amperes and Volts) are those used in
welding. Activated at the end of each welding session.
LED G SYN.
Activated in MIG welding. Lights to signal that the
welding machine is working in synergic mode.
LED H Voltage.
In all MIG welding processes, indicates that the dis-
play N shows the preset voltage or, in combination with
the lighting of LED F, the actual welding voltage.
In MMA mode it remains lit at all times and cannot be
selected.
Indicates that the display N shows the open-circuit volt-
age or welding voltage or, in combination with LED F lit,
the actual welding voltage.
Knob I.
The following values must be adjusted based
on the type of process:
Welding current A, wire speed
, program number JOB.
In the service functions select the abbreviations: Prc,
TRG, HSA, SP, PrF, PoF, Acc, BB, L, Ito, H2O, Fac. In
synergic programs when one measurement is adjusted,
the others also change as a result. All of these values
are shown on the display M.
Knob L.
The following values must be adjusted based
on the type of process:
In synergic MIG the arc length, in conventional
MIG the welding voltage.
Based on the symbol set via the knob I, from the service
13
A
V
M
E
Q
, thickness
F
G
R
P
menu it selects the value set, whether to activate or
deactivate it, or make another choice from within the
function itself.
selection key E and adjusted via the knob I.
For the welding current (LED A) it displays the Amperes.
For the wire speed (LED B) it displays the meters per
minute.
For the thickness (LED C) it displays the millimeters.
For the (LED D) it displays the program number set.
In service functions it displays the abbreviations: Prc,
Sin, (Fac, AF, HS only for MMA mode), TRG, HSA, SP,
PrF, PoF, Acc, bb, L, Ito, H2O, Fac.
For the parameters located within the service functions
that are shown on the display M, see the paragraph ser-
vice functions.
It flashes the message "OPn" if the wire feeder door is
open. In error messages it displays the abbreviation Err.
and the welding voltage in conventional MIG.
For the welding voltage (LED H) it displays the Volts.
For the arc length (LED H) it displays a number between
–9.9 and + 9.9; 0 is the recommended value.
For the parameters located within the MMA service
function that are shown on the display N, see the para-
graph service functions.
For the parameters located within the MIG service func-
tion that are shown on the display N, see the paragraph
service functions.
H
N
O
Display M.
In all welding processes, it numerically
displays the selections made via the
Display N.
In all welding processes it numerically
displays the arc length in synergic MIG
L
Fig. 2
13