Optional Accessories - Makita AF500HP Manual De Instrucciones

Ocultar thumbs Ver también para AF500HP:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
Align the tip of pin nails with the grooves at the bottom of
the magazine and push the whole part of pin nails toward
the firing opening.
Close the slide door firmly.
Nose adapter
CAUTION:
Always lock the trigger and disconnect the hose before
loading the pin nailer. (Fig. 14)
To prevent the surface of workpiece from being scratched
or damaged, use the nose adapter. Before attaching the
nose adapter, remove two screws with the hex wrench
that are securing the contact top cover.
Attach the nose adapter so that its protrusion fit into the
groove in the contact element. (Fig. 15)
Store the nose adapter in place when not in use. The
place for storage is at the back of the slide door.
Open the slide door slightly and set the nose adapter onto
the holder with the slide door slightly opened, and then
close the slide door. Total two nose adapters can be
stored. (Fig. 16)
To take the nose adapter out of the holder easily, push it
out using a hex wrench from back of the slide door.
Connecting air hose
CAUTION:
• When connecting air hose, never place a finger on the
trigger.
Lock the trigger and slip the air socket of the air hose onto
the air fitting on the nailer. Be sure that the air socket
locks firmly into position when installed onto the air fitting.
A hose coupling must be installed on or near the tool in
such a way that the pressure reservoir will discharge at
the time the air supply coupling is disconnected.
OPERATION
CAUTION:
• Always be sure to first place the contact element
against the workpiece before pulling the trigger.
(Fig. 17)
To drive a nail, set the lock lever in the "FREE
position.
Place the contact element against the workpiece and then
pull the trigger. (Fig. 18)
Anti dry fire mechanism
This tool is equipped with an anti dry fire mechanism.
When facing a triggers undepressed position to prevent
the tool from being activated, load more nails to resume
operation.
Jammed nailer
CAUTION:
• Always lock the trigger, disconnect the hose and
remove the nails from the magazine before cleaning a
jam. (Fig. 19)
Open the slide door and remove nails from the magazine.
Press the short top end of the hex wrench and take it out
from the holder. (Fig. 20)
Remove two screws with the hex wrench that are securing
the contact top cover.
10
Take the jammed nails from the nail guide groove that has
appeared.
When it is difficult to take out the jammed nails, further
remove two screws with the hex wrench that are securing
the driver guide cover. Then take them out.
MAINTENANCE
CAUTION:
• Always lock the trigger and disconnect the hose before
attempting to perform inspection or maintenance.
• Never use gasoline, benzine, thinner, alcohol or the
like. Discoloration, deformation or cracks may result.
Maintenance of nailer (Fig. 21)
Always check the tool for its overall condition and loose
screws before operation. Tighten as required. (Fig. 22)
With tool disconnected, make daily inspection to assure
free movement of the contact element and trigger. Do not
use tool if the contact element or trigger sticks or binds.
Draining the tool (Fig. 23)
Disconnect the hose from the tool. Place the tool so that
the air fitting faces down to the floor. Drain as much as
possible.
Cleaning of tool
Blow off dust by using an air duster.
Cap (Fig. 24)
When not in use, lock the trigger and disconnect the hose.
Then cap the air fitting port. (Fig. 25)
When the tool is not to be used for an extended period of
time, lubricate the tool using pneumatic tool oil and store
the tool in a safe place. Avoid exposure to direct sunlight
and/or humid or hot environment. (Fig. 26)
Maintenance of compressor and air hose
(Fig. 27)
After operation, always drain the compressor tank. If
moisture is allowed to enter the tool, It may result in poor
performance and possible tool failure.
Keep the air hose away from heat (over 60°C, over
140°F), away from chemicals (thinner, strong acids or
alkalis). Also, route the hose away from obstacles which it
"
may become dangerously caught on during operation.
Hoses must also be directed away from sharp edges and
areas which may lead to damage or abrasion to the hose.
(Fig. 28)
To maintain product SAFETY and RELIABILITY, repairs,
any other maintenance and adjustment should be
performed by Makita Authorized Service Centers, always
using Makita replacement parts.

OPTIONAL ACCESSORIES

CAUTION:
• These accessories or attachments are recommended
for use with your Makita tool specified in this manual.
The use of any other accessories or attachments might
present a risk of injury to persons. Only use accessory
or attachment for its stated purpose.
If you need any assistance for more details regarding
these accessories, ask your local Makita Service Center.
• Nails
• Air hoses
• Safety goggles
Tabla de contenido
loading

Tabla de contenido