Yamaha EDL13000SDE Manuel Del Propietario página 29

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68
2. Capacity of Electrical Devices Possible
APPLICATION RANGE
EDL-Series
You can operate the KJ-series generator in the
following range.
Typical
Typical
Apparatus
Apparatus
Light and
Light and
heaters
heaters
12.5 kVA
12.5 kVA
EDL13000SDE
EDL13000SDE
KJ-S130VX
(12.5 kW)
(12.5 kW)
24.0 kVA
10.0 kVA
KJ-S240
EDL13000STE
(24.0 kW)
(10.0 kW)
10.0 kVA
14.4 kVA
KJ-T130DX
EDL18000STE
(10.0 kW)
(14.4 kW)
14.4 kVA
24.0 kVA
KJ-T180VX
EDL30000STE
(14.4 kW)
(24.0 kW)
24.0 kVA
15.0 kVA
KJ-T300
EDL15000SDE
(24.0 kW)
(15.0 kW)
15.0 kVA
KJ-S150VX
TIP
NOTE:
(15.0 kW)
¡ The data shown above is only a guideline for
12.5 kVA
approximate load capacities, from generator
KJ-T160DX
(12.5 kW)
model to generator model, with different types of
loads at rated outputs. These values may be
16.8 kVA
different from actual applications because of the
KJ-T210VX
(16.8 kW)
output characteristics peculiar to each load. Note
that the starting current is not taken account of in
NOTE:
these approximate values.
¡ The data shown above is only a guideline for
¡ Connecting a motor.
approximate load capacities, from generator
When connecting to a line starting motor, these
model to generator model, with different types of
generators may be used to start a submerged
loads at rated outputs. These values may be
pump of 5.5kW, 7.5kW, 11.0kW (three-phase).
different from actual applications because of the
When starting the motor, the voltage drops
output characteristics peculiar to each load. Note
immediately. The circuit may be opened if an
that the starting current is not taken account of in
electromagnetic switch is connected to the same
these approximate values.
circuit. When connecting two motors or more,
¡ Connecting a motor.
make sure the total current capacity of the motors
When connecting to a line starting motor, these
does not exceed the total rated current.
generators may be used to start a submerged
¡ Connecting to lights and electric heaters.
pump of 5.5kW, 7.5kW, 11.0kW (three-phase).
When connecting to lights or electric heaters, the
When starting the motor, the voltage drops
generator can be used up to the rated capacity.
immediately. The circuit may be opened if an
When using a single phase, it can be used up to the
electromagnetic switch is connected to the same
rated current.
circuit. When connecting two motors or more,
¡ The power factor is used to determine input of the
make sure the total current capacity of the motors
electrical devices.
does not exceed the total rated current.
¡ Connecting to lights and electric heaters.
When connecting to lights or electric heaters, the
generator can be used up to the rated capacity.
When using a single phase, it can be used up to the
rated current.
¡ The power factor is used to determine input of the
electrical devices.
Commutator
Induction
Commutator
Induction
motor
motor
motor
motor
8.0 kVA
8.0 kVA
––
––
(6.4 kW)
(6.4 kW)
15.0 kVA
7.5 kVA
5.5 kW
––
(12.0 kW)
(6.0 kW)
3 Phases
7.5 kVA
10.5 kVA
5.5 kW
7.5 kW
(6.0 kW)
3 Phases
(8.4 kW)
3 Phases
10.5 kVA
7.5 kW
19.0 kVA
11.0 kW
(8.4 kW)
3 Phases
(15.2 kW)
3 Phases
19.0 kVA
11.0 kW
9.5 kVA
––
(15.2 kW)
3 Phases
(7.6 kW)
9.5 kVA
––
(7.6 kW)
9.5 kVA
5.5 kW
(7.6 kW)
3 Phases
12.5 kVA
7.5 kW
(10.0 kW)
3 Phases
PREPARATION FOR FIRST OPERATION
AC devices
Electric power (W)
= Voltage (V) x Current (A) ÷ Power factor
Power factors of commonly used devices are listed in
the following table.
Single-phase induction motor
Fluorescent lighting and indoor
incandescent lighting
Outdoor incandescent light
and heaters
AC arc welder
¡ Ordinarily, a motor is rated in kW. This does not
refer to motor output.
Motor input kVA
Motor output (HP)
=
Motor efficiency x power factor x 1.34
TIP
NOTE:
¡ If a lighting system is employed together with
some types of computers and inverter air-
conditioners and/or the regulated power supply
for TV sets, the lights might suffer flickering. This
phenomenon is not a trouble of the generator: it is
caused by poor matching between the above-
mentioned regulated power supply and the
generator's automatic voltage regulator. In such a
case, modify the load combination and make sure
no flickering appears any longer.
11
Power factor
0.4 to 0.6
0.4 to 0.6
1.0
0.4 to 0.6
Tabla de contenido
loading

Este manual también es adecuado para:

Edl13000steEdl15000sdeEdl18000steEdl30000ste

Tabla de contenido