THE WHITE OPERATION CONTROL LIGHT SWITCHES OFF AND THE LID DOES NOT OPEN
-
Check if swich IB is on (AUX light on). Check fuse F4. Otherwise:
-
You need to intervene on the lid closing lock which is situated on the front of the
machine (see illustration 1).
-
Unscrew the two front screws and take off the stainless steel protection.
-
Slightly unscrew the set screw A.
-
Turn screw B towards the right so that the seat on the screw coincides with the
pointer ◄ (see illustration 2).
-
The lid closing device is now manually disenabled and the lid opens.
Warning! : While the lid is open, take the screw B back to its initial position ( see
illustration 1) and fasten the set screw A. Thus, the safety device is reactivated.
DURING THE OPENING OF THE LID THE BASKET DOES NOT STAND COMPLETELY STILL
Check speed sensor SE and inverter IN
-
Instruction manual for installation, maintenance and use
Centrifuge DRC 700V
:
DRC700V-GB-00
:
:
11 di 21
Page