To remove, work the disposal bag up,
and pull it out toward the rear via the
vacuum socket. Seal off the disposal
bag with the closing strip.
After vacuuming wet debris, always
remove the disposal bag.
When inserting a fleece filter bag, take
care that the closing cover and the
fleece filter bag face completely
against the inside wall of the con-
tainer. The cardboard flange of the
fleece filter bag must be pulled over
the collar of the vacuum socket.
After removing the fleece filter bag,
seal it with the closing cover in order
to avoid debris.
Audio signal (see page 12)
Only for Dustex 35 MX (**): Set the
selector switch for the vacuum-hose
diameter to the appropriate value.
When the air velocity falls below
20 m/s, an audio signal will sound.
Empty the container and/or check the
vacuum system for clogs.
Vacuum cleaner socket outlet
(see page 11)
The switch position for switching the
vacuum cleaner on is shown on
page 11/12.
In switch position
cleaner automatically starts as soon as
the power tool connected to it is
switched on.
Switch the vacuum cleaner off before
connecting a power tool to the vac-
uum cleaner's socket outlet. Make
sure that the power tool is switched
off when inserting its plug into the
vacuum cleaner's socket outlet.
After switching off a power tool con-
nected to the vacuum cleaner's socket
outlet, the vacuum cleaner will run on
for approx. 15 seconds and then
automatically switch off.
Wet vacuuming (see page 17)
When wet vacuuming electrically
conductive liquids, the vacuum
cleaner is automatically switched off
(automatic shut-off) when reaching
the maximum filling height of the
container. Pull the mains plug from
the socket outlet and empty the
container.
When wet vacuuming electrically
non-conductive liquids (e. g., oils,
drilling emulsions), the vacuum
cleaner is not automatically switched
off when reaching the maximum filling
height of the container. Empty the
container in time.
Switch the vacuum cleaner off imme-
diately as soon as foam or water
comes out, and empty the container.
After completion of the wet vacuum-
ing, clean the sensors and their
intermediate area using a brush (see
page 16).
Accessories (see page 9/20)
Mount accessories applying only slight
, the vacuum
pressure. For disassembling, turn the
parts somewhat against each other
and pull apart.
Transport
a crane hook. Otherwise, you could
injure yourself or damage the vacuum
cleaner.
The vacuum cleaner is not suit-
able for handling by crane. Do
not hang the vacuum cleaner to
en
35