FIXING OF THE STOPS
A
B
D
C
E
Set the opening limit switch of the geared motor as follows:
A. Unlock the geared motor
B. Loosen the mechanical stop screw.
C. Place the gate leaf manually in the desired opening position.
D. Then place the mechanical stop against the pivot and tighten the screws.
E. Place the gate leaf manually in the closed position and lock the gear motor.