Tabla de contenido
Parts and Functions

Outdoor Unit

For models:
HSU-07HC03/R2 HSU-09HC03/R2
CONNECTING PIPING AND
ELECTRICAL WIRING
INLET
OUTLET
The machine is adaptive in following situation
1. Applicable ambient temperature range:
Cooling
Heating
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F.
3. If the fuse on PC board is broken please change it with the type of T.3.15A/250V.
4. The distance between the indoor unit and the floor should be more than 2m.
5. The wiring method should be in line with the local wiring standard.
6. After installation, the power plug should be easily reached.
7. The waste battery should be disposed properly.
8. The appliance is not intended to use by young children or infirm persons without supervision
9.Young children should be supervised ensure that they do not play with the appliance.
10.The appliance must be installed on strong enough supporter.
11 .The wiring diagram is attached inside the machine.
All manuals and user guides at all-guides.com
Maximum:D.B/W.B
Indoor
Minimum:D.B/W.B
Maximum:D.B/W.B
Outdoor
Minimum:D.B
Maximum:D.B
Indoor
Minimum:D.B
Maximum:D.B/W.B
Outdoor
Minimum:D.B/W.B
DRAIN HOSE
4
o
o
32
C/23
C
o
o
18
C/14
C
o
o
43
C/26
C
o
18
C
o
27
C
o
15
C
o
o
24
C/18
C
o
o
-7
C/-8
C

Hide quick links:

Tabla de contenido
loading

Tabla de contenido