PERFORMANCE DATA SHEET (PB35)
PB35 Filter System with PB35-10 Cartridge
OMNIFILTER PB35 Filter Housing
Replacement Component Model Numbers:
OMNIFILTER PB35-10 Filter Cartridge

Installation Requirements:

• Do not use with water that is unsafe or of unknown quality without
adequate disinfection before or after the system.
• Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
• While testing was performed under laboratory conditions, actual
performance may vary.
The PB35 is Tested and Certified by NSF International
against CSA B483.1 and NSF/ ANSI Standard 53 for the
reduction of Lead and Cysts.
• This system has been tested in accordance to NSF/ANSI 53 for the
reduction of the substances listed below. The concentration of the
indicated substance in water entering the system was reduced to
a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI 53.
Influent Challenge
Substance
Concentration
Standard 53
Minimum
Cyst**
50,000
Microsphere/L
Lead (pH 6.5)
0.15 mg/L ± 10%
Lead (pH 8.5)
0.15 mg/L ± 10%
**NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and Giardia
by mechanical means.
EPA Est. 090375-MEX-001
Rated Capacity:
Min-Max operating pressure:
Min-Max operating temperature:
Rated Service Flow (gpm):
IOWA RESIDENTS ONLY:
Store or seller's name
Address
City State
Telephone
Seller's signature
Customer's signature
Maximum
Permissible
Reduction
Average
Product Water
Requirements
Reduction
n/a
≥99.95%
>99.99%
0.010 mg/L
n/a
98.8%
0.010 mg/L
n/a
99.0%
20, 000 Gallons
30 – 100 psi
40°-100°F
5 gpm
Zip
Date
PERFORMANCE DATA SHEET (PB55)
PB55 Filter System with PB55-20 Cartridge
OMNIFILTER PB55 Filter Housing
Replacement Component Model Numbers:
OMNIFILTER PB55-20 Filter Cartridge
Installation Requirements:
• Do not use with water that is unsafe or of unknown quality without
adequate disinfection before or after the system.
• Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
• While testing was performed under laboratory conditions, actual
performance may vary.
The PB55 is Tested and Certified by NSF International
against CSA B483.1 and NSF/ ANSI Standard 53 for the
reduction of Lead and Cysts.
• This system has been tested in accordance to NSF/ANSI 53 for the
reduction of the substances listed below. The concentration of the
indicated substance in water entering the system was reduced to
a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI 53.
Influent Challenge
Substance
Concentration
Standard 53
Minimum
Cyst**
50,000
Microsphere/L
Lead (pH 6.5)
0.15 mg/L ± 10%
Lead (pH 8.5)
0.15 mg/L ± 10%
**NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and Giardia
by mechanical means.
EPA Est. 090375-MEX-001
Rated Capacity:
Min-Max operating pressure:
Min-Max operating temperature:
Rated Service Flow (gpm):
Maximum
Permissible
Reduction
Average
Product Water
Requirements
Reduction
n/a
≥99.95%
>99.99%
0.010 mg/L
n/a
98.8%
0.010 mg/L
n/a
99.0%
40, 000 Gallons
30 – 90 psi
40°-100°F
10 gpm
• 5 •