• Never use liquids other than water.
• Please observe the safety notes and the additional notes so as to avoid damage.
Initial use
• Remove the packaging material.
• Check the device, mains plug and cable for damage.
• Place the air humidifier on a even, firm, flat and humidity-resistant surface. Ensure that the air humidi-
fier cannot be knocked over.
• Position the air humidifier in a raised place, e.g. a table, chest of drawers, chair or bedside table. To
avoid damage from the escaping mist, the device must not be placed on the floor.
• Ensure than the top is placed firmly on the base. Pull the mist outlet upwards until it noticeably en-
gages. For this purpose, you must overcome the rest resistance in the initial position with a forceful tug.
• Make sure that the escaping mist is not directed at the bottle, wall, plug socket or other objects and
that the air outlet always remains free.
• Fill a 0.5 litre plastic water bottle with clean tap water, distilled water or still water. Do not use carbon-
ated water. The manufacturer expressly recommends the use of distilled water so as to avoid limescale.
The water temperature may be a maximum of 50 °C, so as to avoid damage to the device.
• Fasten a bottle adapter onto the bottle. There are two adapters available that fit most standard plastic
bottles:
• 1. "PC 1810" thread with a thread diameter of 28 mm and
• 2. "30/25" thread with a thread diameter of 30 mm.
• Turn the bottle upside down and place it in the top of the air humidifier. Do not compress the plastic
bottle. The base will fill with water automatically.
• Connect the power supply unit connector plug with the connector socket of the air humidifier and insert
the power supply unit into the socket. Ensure that the cable does not pose a trip hazard.
• Turn the control dial clockwise (to the right) to switch on the air humidifier.
Use the device and switch off
IMPORTANT
• The immediate vicinity of the air humidifier may become damp. Reduce the nebulisation per-
formance or put the device in a more suitable place.
• Calcareous water can leave white deposits. Use distilled water instead.
• If the device should accidentally tip over, water may escape, even if the device is switched off
and unplugged.
• Check the humidity of your ambient air regularly. Intensive continuous operation can cause the
ambient air to become excessively humid. The relative air humidity should not exceed 60%.
• By turning the control dial to the right, you can adjust the nebulisation performance between "MIN"
and "MAX".
• Through operation, the device and the water in the base warm up.
• The air outlet is illuminated in blue when there is enough water.
• To switch the air humidifier on again, turn the control dial to the left.
• If there is not enough water, the device will switch OFF (red LED).
• Switch off the device when refilling the bottle with water. Change the water in the bottle every day so
that fresh water is always taken in.
14