SYMPTOM
POSSIBLE CAUSE
Lights will not
1. Light switch is turned off.
come on.
2. Light bulb is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect.
5. Sensor not detecting movement.
6. Incorrect circuit wiring, if this is a new installation.
Lights come on in
1. Light control may be installed in a relatively dark location.
daylight.
2. Light control is in TEST.
Lights come on for
1. Light control may be sensing small animals or automobile
no apparent reason.
2. Sensitivity is set too high.
Lights stay on
1. The sensor may be picking up a heat source like an air
continuously.
2. Light control is in Manual Mode.
3. Light control is in DualBrite® mode.
4. Sensitivity is set too high.
Lights flash on
1. Light control is in the TEST mode and warming up.
and off.
2. Heat being reflected from other objects may be affecting
Range .................................................Up to 30 ft. (9.1 m) [varies with surrounding temperature]
Sensing Angle.....................................Up to 180°
Electrical Load ...................................Up to 100 Watt Maximum Incandescent
Bulb Type ...........................................Medium Base, Type "A", 100 Watt Maximum
Sensor Capacity ..................................Up to 360 Watt (3.0 A) Maximum Tungsten
Power Requirements ...........................120 VAC, 60 Hz
Operating Modes ...............................TEST, AUTO, and MANUAL MODE
ON-Timer ..........................................1, 5, 10 minutes
DualBrite® Timer ...........................Off, 3, 6 hours, dusk-to dawn
Test Timer ..........................................5 Seconds
Manual Mode Timer ..........................Dusk-to-Dawn
HeathCo LLC reserves the right to discontinue products and to change specifications at any time
without incurring any obligation to incorporate new features in products previously sold.
TROUBLESHOOTING GUIDE
traffic.
vent, dryer vent, or brightly painted, heat-reflective
surface.
the sensor.
SPECIFICATIONS
SOLUTION
1. Turn light switch on.
2. Check bulb and replace if burned out.
3. Replace fuse or turn circuit breaker on.
4. Recheck after dark.
5. Increase sensitivity.
6. Verify wiring is correct.
1. The fixture is operating normally under these
conditions.
2. Set control switch to 1, 5, or 10 minutes.
1. Reduce sensitivity.
2. Reduce sensitivity.
1. Reduce sensitivity.
2. Switch to Auto.
3. Slide DualBrite® switch to OFF position.
4. Reduce sensitivity.
1. Flashing is normal under these conditions.
2. Reduce sensitivity.
8
205072-02