INSTALLATION
WARNING: Turn power off at circuit
breaker or fuse. Place tape over circuit
breaker switch and verify power is off at
the fixture.
For best performance, mount the fixture about 6
feet (1.8 m) above the ground.
1. Remove two decorative nuts.
2. Remove X-Bar.
3. Tighten mounting screws finger tight against
X-Bar.
4. Attach X-Bar to junction box.
Decorative Nut
X-Bar
G N
D
Bracket
Mounting
Screws
Note: We recommend having an assistant help
hold the decorative light during the wiring process.
Note: All wiring must be run in accordance with
the National Electrical Code through conduit
or another acceptable means. Contact a quali-
fied electrician if there is any question as to the
suitability of the system.
Fixture Base
X-Bar
or Bare
Fixture Mounting
Screw
Junction
Box
Ground Screw
2
WIRING
CAUTION: DO NOT connect the RED
wire unless you want to control other
lights from the motion sensor (see Op-
tional Wiring).
Black
Green
White
One Motion Light
White
Black
Green
or Bare
Two Motion Lights
Light
Fixture
Light
Light
Fixture
Fixture
205072-02