PARAMETER
VALUE
rA.AP
0 - 1 00
rA.Ch
0 - 1 00
St .AP
PAUS
ChiU
no
St .Ch
StoP
APEr
St .PA
ChiU
no
PAUS
Ch.AU
no
0.5" - 20'0
Ch.tr
no
0.5" - 20.0'
PA.tr
Si
no
DESCRIPTION
Slow down in opening
This menu allows regulating the percentage of the ride/drive that is carried
out at reduced speed during the last opening stretch
Slow down in closing
This menu allows regulating the percentage of the ride/drive that is carried
out at reduced speed during the last closing stretch.
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the opening phase.
The barrier closes and enters in pause
The barrier immediately starts to reclose
The barrier continues to open (the command is ignored)
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the closing phase
The barrier closes and the cycle is considered concluded
The barrier reopens
Start command during the pause
This menu allows establishing the behavior of the control units if a Start
command is received while the barrier is opened in pause.
The barrier starts to reclose
The command is ignored
The pause time becomes recharged (
Automatic Closing
In automatic operation, the control unit automatically recloses the barrier
at the end of the preset time
Function deactivated
The barrier recloses after the time set
Closing after transit
During the automatic operation, the pause count down starts from the set
up value each time a photocell operates during the pause.
If the photocell operates during the opening time, this time will be
immediately stored as pause time.
This function allows having a fast closing after the transit through the
barrier, for which usually a lesser time for
used.
Function deactivated
The barrier recloses after the time set
Pause after the transit
In order to render minimum the time in which the barrier remains open,
it is possible to make the barrier close as soon as the passage in front of
photocells has ended. If the automatic operation is enabled, the
value is loaded/programmed as time of pause
Function deactivated
Ch.AU
)
Ch.AU
(automatic closing) is
- 53 -
DEFAULT
MEMO
10
10
PAUS
StoP
ChiU
no
no
no
Ch.tr