Preparation
PREPARE THE OPENING
The Advantium 240V can be installed in
combination with other GE/Monogram
appliances. Always follow each product's
Installation Instructions to complete the
installation.
30"
17-1/2"
36-3/4"
Min.
Single Advantium 240V Installation:
Order a 30" wide single oven cabinet or cut the
opening in a wall to the dimensions shown.
• Always maintain 36-3/4" minimum height from
the floor to the cutout in any single or combined
installation.
• Allow 2-1/8" case trim overlap on the sides and
7/8" overlap on the bottom of the opening for
all models. Allow 1-1/4" case trim overlap on
the top for models PSB9120 and 3/4" overlap
on the top for models ZSC2200, ZSC2200,
ZSC2201 and ZSC2202.
• Oven overlaps will conceal cut edges on all
sides of the opening.
When installed over a single oven or a warming
drawer, allow at least 2" between the two
openings. This separation will provide clearance
for bottom overlap of the Advantium 240V and
the other appliance overlaps.
Construct a solid oven floor of 3/8" min. thick
plywood supported by 2 x 4 or 2 x 2 runners on all
sides.
• The support must be level and rigidly mounted,
flush with the bottom edge of the cutout.
Installation Preparation
WITHOUT
23-1/2"
25-1/4"
Construct
Base
Min. 3/8"
Plywood
Supported
by 2x4
or 2x2
Runners all
Four Sides

an Accessory Storage Drawer

PREPARE THE OPENING
Installation over a GE/Monogram
Warming Drawer:
30"
17-1/2"
36-3/4"
Min.
NOTE: Additional clearances between the cutouts
may be required. Check to be sure the oven
supports above the Warming Drawer location do
not obstruct the required interior depth and height.
See Warming Drawer installation instructions for
details.
6
(CONT.)
23-1/2"
Construct
Solid Bottom
Min. 3/8"
Plywood
Supported
by 2x4 or 2x2
25-1/4"
Runners all
Four Sides
2" Min.
(3"
recommended)
Per warming
drawer
requirement
Tabla de contenido
loading

Tabla de contenido