Before use of the power tool, all live cables or other items carrying electric voltage within the area in which
the user is working must be switched off. If this is not possible, the corresponding safety precautions for
working in the proximity of live cables or equipment must be implemented and observed.
▶ Use only Hilti lithiumion batteries of the B 22 series with this product.
▶ Use only Hilti battery chargers of the C4/36 series for charging these batteries.
3.3
Possible misuse
•
Do not use this hand-held product clamped in a fixed position or as a stationary device.
•
Do not use the product in heavy rain or under water.
3.4
Lithiumion battery status display
The charge state of the Li-ion battery and malfunctions of the product are indicated by the indicator of the
Liion battery. The charge status of the Liion battery is indicated after one of the two battery release buttons
is short-pressed.
Status
4 LEDs light.
3 LEDs light.
2 LEDs light.
1 LED lights.
1 LED flashes.
Battery state of charge cannot be displayed while the control switch is pressed and for up to 5 seconds
after releasing the control switch. If the LEDs of the charge state indicator flash, follow the instructions
in the 'Troubleshooting' section.
3.5
Items supplied
Crimping / pressing tool, operating instructions.
Other system products approved for use with this product can be found at your local HILTI STORE or online
at: www.hilti.group
3.6
Selection of the connecting material
A table to assist with selecting the type of cable and cable terminal to be used can be found at the end of
these operating instructions.
4
Technical data
Rated voltage
Weight in accordance with EPTA procedure 01
Max. crimping force
Crimping time
Max. permissible crimping capacity
Storage temperature
Ambient temperature for operation
4.1
Noise information and vibration values in accordance with EN 60745
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure. The data given represents the main applications of the power tool.
*2207049*
Printed: 26.10.2018 | Doc-Nr: PUB / 5436011 / 000 / 02
Meaning
•
•
•
•
•
2207049
State of charge: 75 % to 100 %
State of charge: 50 % to 75 %
State of charge: 25 % to 50 %
State of charge: 10 % to 25 %
State of charge: < 10 %
NCR 060 II-A22
21.6 V
2.98 kg
53 kN
≈ 5 s
•
•
−20 ℃ ... 70 ℃
−17 ℃ ... 60 ℃
500 MCM (240
mm²) Cu
350 MCM
(240 mm²) Al
English