ATTENTION!
Check the motor rotation direction.
12.3
INSTALLATION K07 – K12
The unit comes packaged as follows:
Unit inlet port closed for protection. (1)
Intake silencer housing and manifold assembled together,
separate from the blower. (2)
The package contains: gasket, 4 screws, wrench ch13.
12.3.1
Installation with 90° manifold:
Remove the protection from the inlet port
Place the gasket on the blower inlet port.
Select the required position (see housing repositioning
diagrams in the first section).
Place the manifold with silencer housing on the inlet port.
Tighten the screws with the wrench provided.
See silencer housing repositioning diagrams in the first section.
12.4
INSTALLATION WITHOUT 90° MANIFOLD
All the units can be assembled without manifolds.
NOTE FOR THE USER
See silencer housing repositioning diagrams in the first section.
Undo the manifold screws.
Undo the silencer housing screws.
Place the gasket on the blower inlet port.
Place the silencer housing on the blower inlet port.
Tighten the screws.
Danger due to rotating parts: impeller!
The danger of shearing due to the rotating impeller can exist even when the machine off, if it is started manually.
Therefore use suitable work clothes and personal protection equipment.
12.5
VERTICAL INSTALLATION ON THE COVER
The units can be installed with the working axis vertical, as follows:
Using vibration dampers fitted directly on the cover, without manifold.
Non-compliance with the unit's intended use can cause serious
injury.
Regularly check the fixing of the unit to the support structure.
Excessive vibration of the unit can seriously damage the machine.
The vibration dampers are not included but are available on request.
NOTE FOR THE USER
Avoid the possibility of water stagnation, especially in case of
ATTENTION!
installation of the unit with vertical axis.
ATTENTION!
Check the motor rotation direction.
FPZ-MI-K-TD-MOR-IE2WR-15-R02
(see par. 5.6.3 ROTATION DIRECTION)
1
(see par. 5.2 ROTATION DIRECTION)
38 / 117