Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

PHASE ROTATION METER
PROBADOR DE FASE &
ROTACIÓN
E N G L I S H
E S PA Ñ O L
User Manual
Manual de instrucciones
L1/A
L2/B
L3/C
690V
600V CAT III
300V CAT IV
L1L2L3
L
R
PHASE ROTATION
MODEL 6608
6608

Capítulos

Tabla de contenido
loading

Resumen de contenidos para AEMC Instruments 6608

  • Página 1 6608 PROBADOR DE FASE &  ROTACIÓN L1/A L2/B L3/C 690V 600V CAT III 300V CAT IV L1L2L3 PHASE ROTATION MODEL 6608 E N G L I S H User Manual Manual de instrucciones E S PA Ñ O L...
  • Página 2 For verification, please use our calibration services. Refer to our repair and calibration section at www.aemc.com. Serial #: ____________________________ Catalog #: 2121.10 Model #: 6608 Please fill in the appropriate date as indicated: Date Received: ________________________ Date Verification Due: _____________________ Chauvin Arnoux , Inc.
  • Página 3: Tabla De Contenido

    Table of Contents INTRODUCTION ............2 1.1 International Electrical Symbols ........3 1.2 Definition of Measurement Categories ......3 1.3 Receiving Your Shipment ..........4 1.4 Ordering Information ............4 1.4.1 Accessories and Replacement Parts .....4 PRODUCT FEATURES ..........5 2.1 Description ..............5 2.2 Control Features.............5 SPECIFICATIONS ............6 OPERATION ..............7 4.1 Phase Rotation Direction..........7 MAINTENANCE ............
  • Página 4: Introduction

    • For your own safety, and to prevent any damage to your instru- ment, you must follow the instructions given in this manual. • This instrument can be used on category III electrical circuits not exceeding 600V with respect to earth. It must be used indoors, in an environment not exceeding pollution level 2, at an altitude of not more than 2000m. The instrument can therefore be used in complete safety on 400V and 690V three-phase networks in an industrial environment. • For safety reasons, you must use only measurement leads having a voltage rating and category at least equal to those of the instru- ment and compliant with standard IEC 61010-031. • Do not use if the housing is damaged or not correctly closed. • Do not place your fingers near unused terminals. • If the instrument is used other than as specified in this manual, the protection provided by the instrument may be impaired. • Do not use this instrument if it seems to be damaged. • Check the integrity of the insulation of the leads and of the hous- ing. Replace damaged leads. • Be prudent when working in the presence of voltages exceeding or 33Vrms and 46.7Vpp; such voltages can cause a risk of electrocution. The use of individual protections is recommended in some cases. • Always keep your hands behind the physical guards of the probe tips or alligator clips. • Always disconnect all leads from the measurement and from the instrument before opening the housing. Phase Rotation Meter Model 6608...
  • Página 5: International Electrical Symbols

    1.2 Definition of Measurement Categories CAT I: Measurement category I corresponds to measurements taken on circuits not directly connected to the network. CAT II: Measurement category II corresponds to measurements taken on circuits directly connected to the installation. Example: measurement for electrodomestic units, portable tools and analogue devices CAT III: Measurement category III corresponds to measure- ments on building installations. Example: measurement on distribution panels, cabling, etc. CAT IV: Measurement category IV corresponds to measure- ments taken at the source of low-voltage installations Example: metering and measurements on overvoltage protection devices. Phase Rotation Meter Model 6608...
  • Página 6: Receiving Your Shipment

    1.4 Ordering Information Phase Rotation Meter Model 6608 ......Cat. #2121.10 Includes meter, three color-coded test leads (red, black, blue), three alligator clips (black), soft carrying case and a user manual. 1.4.1 Accessories and Replacement Parts Soft carrying case .............
  • Página 7: Product Features

    PRODUCT FEATURES 2.1 Description The Model 6608 is designed to facilitate installing three-phase elec- trical power supply networks by allowing a rapid determination of the direction of phase rotation 2.2 Control Features 1. Test lead input terminals 2. Phase indicators L1, L2, L3 3. Clockwise and counter- L1/A L2/B L3/C clockwise rotation LED 690V 600V CAT III 300V CAT IV L1L2L3 PHASE ROTATION MODEL 6608 Phase Rotation Meter Model 6608...
  • Página 8: Specifications

    -4° to 122°F (-20° to 50°C); RH < 80% Temperature SAFETY CAT III 600V IEC 61010-1, DIN VDE 0411; Safety Rating IEC 61557-7, DIN VDE 0413-7; Tightness : IP 40 (as per IEC 60529 Ed.92) Double Insulation CE Mark Phase Rotation Meter Model 6608...
  • Página 9: Operation

    CHAPTER 4 OPERATION 4.1 Phase Rotation Direction On a three-phase electrical network: Connect the three leads to the instrument, matching the mark- ings. Connect the three alligator clips to the 3 phases of the network to be tested. The display lights up, indicating that the instrument is in opera- tion. When the three phase indicators (L1, L2, L3) are lit, the clockwise (or counter-clockwise) rotation arrow indicates the direction of phase rotation. Warning: The wrong direction of rotation may be displayed if a lead is connected in error to the neutral conductor. Refer to the instrument’s back label for a summary of the various display possibilities. Phase Rotation Meter Model 6608...
  • Página 10: Maintenance

    CHAPTER 5 MAINTENANCE 5.1 Cleaning To avoid electrical shock or damage to the meter, do not get water inside the case. • Periodically wipe the case with a damp cloth and mild detergent • Dry completely before using again. • Do not use abrasives or solvents. Phase Rotation Meter Model 6608...
  • Página 11: Repair And Calibration

    NOTE: You must obtain a CSA# before returning any instrument. Technical and Sales Assistance If you are experiencing any technical problems, or require any assistance with the proper operation or application of your instrument, please call, mail, fax or e-mail our technical support hotline: ® ® Chauvin Arnoux , Inc. d.b.a. AEMC Instruments 200 Foxborough Boulevard • Foxborough, MA 02035, USA Phone: (800) 343-1391 or (508) 698-2115 Fax: (508) 698-2118 [email protected] www.aemc.com NOTE: Do not ship Instruments to our Foxborough, MA address. Phase Rotation Meter Model 6608...
  • Página 12: Limited Warranty

    Limited Warranty The Model 6608 is warranted to the owner for a period of two years from the date of original purchase against defects in manufacture. This limited ® warranty is given by AEMC Instruments, not by the distributor from whom it was purchased. This warranty is void if the unit has been tampered with, ® abused or if the defect is related to service not performed by AEMC Instruments.
  • Página 13 CARACTERÍSTICAS DEL PRODUCTO ....... 15 2.1 Descripción..............15 2.2 Características de los Controles ........15 ESPECIFICACIONES ..........16 OPERACIÓN .............. 17 4.1 Sentido de rotación de fases ........17 MANTENIMIENTO ............. 18 5.1 Limpieza ...............18 Reparación y Calibración .............19 Asistencia Técnica y de Ventas ............19 Garantía Limitada .................20 Reparaciones bajo Garantía............20 Medidor De Rotación De Fase Modelo 6608...
  • Página 14: Introducción

    Si el instrumento se utiliza de una forma no especificada en el presente manual, la protección proporcionada por el instrumento puede verse alterada. • No utilice este aparato si parece estar dañado. • Controle que el aislamiento de los cables y la carcasa estén en perfecto estado. Cambie los cables que estén dañados. • Tenga cuidado cuando trabaje con tensiones superiores a 70Vdc o 33Vrms y 46,7Vpp, estas tensiones pueden producir electrocu- ción. Dependiendo de las condiciones, se recomienda el uso de protecciones individuales. • Mantenga siempre sus manos detrás de las protecciones de las puntas de prueba o los clipes de cocodrilo • Desconecte siempre las puntas de prueba de los puntos de medida y del instrumento antes de abrir la carcasa. Medidor De Rotación De Fase Modelo 6608...
  • Página 15: Símbolos Eléctricos Internacionales

    CAT III : Medición de la categoría III corresponde a las medicio- nes en las instalaciones en edificios. Ejemplo: cuadro de distribución, disyuntores, máquinas o aparatos industriales fijos. CAT IV : Medición de la categoría IV corresponde a las medicio- nes adoptadas en instalaciones de baja tensión. Ejemplo: entradas de energía, contadores y dispositi- vos de protección. Medidor De Rotación De Fase Modelo 6608...
  • Página 16: Recibiendo Su Pedido

    Incluye medidor con tres cables de prueba (rojo, negro y azul), tres clips tipo cocodrilo, un maletín de transporte blando y manual del usuario. 1.4.1 Accesorios y repuestos Maletín de transporte blando ......... Cat. N° 2121.54 Conjunto de 3 cables con código de color con clips tipo cocodrilo negros CAT III 1000V 10A ..Cat. N° 2121.55 Medidor De Rotación De Fase Modelo 6608...
  • Página 17: Características Del Producto

    2. Indicadores de fase L1, L2 y L3 L1/A L2/B L3/C 3. Simbolo LCD de rotacion en 690V 600V CAT III 300V CAT IV el sentido horario y contra L1L2L3 horario PHASE ROTATION MODEL 6608 Medidor De Rotación De Fase Modelo 6608...
  • Página 18: Especificaciones

    -4° hasta 122°F (-20° hasta 50°C); RH < 80% Almacenamiento SEGURIDAD CAT III 600V Calificación de IEC 61010-1, DIN VDE 0411; Seguridad IEC 61557-7, DIN VDE 0413-7; Hermeticidad : IP 40 (según IEC 60529 Ed.92) Doble Aislamiento Marca CE Medidor De Rotación De Fase Modelo 6608...
  • Página 19: Operación

    CAPÍTULO 4 OPERACIÓN 4.1 Sentido de rotación de fases En una red eléctrica trifásica : Conecte los 3 cables al instrumento de forma que correspon- dan a las marcas. Conecte las 3 pinzas cocodrilo a las 3 fases de la red a probar. La puesta en marcha del display indica que el instrumento funciona. Cuando los 3 indicadores (L1, L2, L3) de fases están encen- didos, la flecha de rotación en el sentido horario (o en el sentido contrario) indica el sentido de rotación de fases. Atención: se puede visualizar un sentido de rotación incorrecto si un cable se ha conectado, por error, al neutro de la red. Consulte la etiqueta del instrumento para obtener un resumen de los diversos posibilidades de visualización. Medidor De Rotación De Fase Modelo 6608...
  • Página 20: Mantenimiento

    CAPÍTULO 5 MANTENIMIENTO 5.1 Limpieza Periódicamente limpie la carcasa con un trapo mojado con detergente. Séquelo completamente antes de utilizarlo. No utilice productos abrasivos. ADVERTENCIA: Para evitar cortocircuitos o dañar el instrumento, no introduzca agua dentro de la carcasa. Medidor De Rotación De Fase Modelo 6608...
  • Página 21: Reparación Y Calibración

    NOTA: Todos los clientes deben obtener un a CSA# antes de enviar cualquier instrumento. Asistencia Técnica y de Ventas Si tiene cualquier problema técnico o necesita ayuda para la correcta ope- ración o aplicación de su instrumento por favor llame, escriba, envíe un fax o e-mail a nuestro soporte técnico: Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® 200 Foxborough Boulevard • Foxborough, MA 02035, USA Phone: (800) 343-1391 or (508) 698-2115 Fax: (508) 698-2118 [email protected] www.aemc.com NOTA: No envíe instrumentos a nuestra dirección en Foxborough, MA. Medidor De Rotación De Fase Modelo 6608...
  • Página 22: Garantía Limitada

    Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® Service Department • 15 Faraday Drive • Dover, NH 03820 USA Tel: (800) 945-2362 or (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 or (603) 749-6309 [email protected] Precaución: Para protegerse contra pérdidas en tránsito, le recomenda- mos asegurar su mercadería. NOTA: Todos los clientes deben obtener un CSA# antes de enviar un instrument Medidor De Rotación De Fase Modelo 6608...
  • Página 24 03/17 99-MAN 100336 v4 Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® 15 Faraday Drive • Dover, NH 03820 USA www.aemc.com...

Tabla de contenido