Power Supply And Motor - V2 HEAVY2 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

9 - POWER SUPPLY AND MOTOR

The control unit must be powered by an electric wire protected
by a differential magnetothermic switch in compliance with
current legislation.
The control unit can drive a 230V/400V three-phase motor with
delta connection.
The power needed depends on the kind of motor used and can
be one of three kinds:
• 400V three phase
• 230V three phase
• 230V single phase
The following layouts show how the power and cables on the
motor should be connected and how the voltage selection
connector in each case should be set up.
400V THREE PHASE
MOTOR
230V THREE PHASE
MOTOR
U3
U2
U1
M
3~
U3
U2
U1
M
3~
m
IMPORTANT: before connecting the power supply,
make sure the voltage selection connector (J1) has been
properly set up. Incorrect setting could seriously damage
the control unit
m
Connect the grounding conductor of the motors to the
grounding system of the power supply (the HEAVY2 unit is
equipped with two dedicated terminals: W1 and W2).
m
IMPORTANT: the control unit provides no protection to
the motors. A motor protection device should be installed
before the motor.
VOLTAGE SELECTOR
W1
W2
VOLTAGE SELECTOR
W1
W2
- 32 -
J1
W3
W4
W5
MAINS
T
S
R
J1
W3
W4
W5
MAINS
T
S
R
Tabla de contenido
loading

Este manual también es adecuado para:

Heavy2-pbHeavy2-mb

Tabla de contenido