Description Of The Case Poolwatch Top Eco Inorganic Chlorine - Astralpool POOLWATCH TOP ECO 29485 Manual De Instrucciones

Cloro inorgánico no estabilizado ºc/ph/ppm cl/mv ppm cl no estabilizado célula galvánica autolimpiable
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

6. DESCRIPTION OF THE CASE POOLWATCH TOP ECO INORGANIC CHLORINE

1 . - 4 ARROW KEYBOARD: We can move in the display through these arrows when we enter the programme.
2 . -DISPLAY LCD: Back lightened display that shows the pH value and its set point value. It also shows the Inorganic Chlorine value in
ppm and its set point value. The arrow to the right of the set point value shows if an pH enhancer is being used when it is upwards
and it is downwards, shows that a pH reducer
3 .- VAL BUTTON: It is used to validate.
4.- ENTER BUTTON: It is used to enter the programme and for the programme itself.
5 .- ESC BUTTON: It is used to go out of the programme.
6.- SP1 PILOT: When it is enlighted, it shows that the pump relay number 1 is switched on (reading ORP).
7.- SP2 PILOT: When it is enlighted, it shows that the pump relay number 2 is switched on (readingCl).
8.- SP3 PILOT: When it is enlighted, it shows that the pump relay number 3 is switched on (reading pH).
9.- SP4 PILOT: When it is enlighted, it shows that the pump relay number 4 is switched on (reading Temperature).
8
7. DRAW OF THE CASE
                   
8. pH ELECTRODE AND Cl CELL PLANNING AND ADJUSTMENT
Before switching on the PoolWacht Top Eco Inorganic Chlorine it is recommended to have the water in the pool box between
7-7.6 pH units and between 1-1.5 ppm of the available residual Chlorine (DPD nº1).
1.- Put the starter command of the dispenser pump in 0 position (off).
2.- Keep closed the inlet and outlet valve water to the analysis chamber.
3.- Take the pH probe out of its original container.
4.- Connect the pH probe to the cable connector on the left (corresponding to the connector 31 blue heald (-) and 32 active (+)
translucent.
5.- Fill the jug to calibrate with buffer solution pH 7. Put the buffer solution in the inferior part of the electrode. Follow the signal flow
graph planning of the equipment. Go to adjustment and select the pH parameter. Introduce "SENSOR pH" and press "ENTER".
Some bars will appear on the LCD screen. Once the calibration is finished, the sentence "STABLE READING" will appear on
screen. We will press validate (VAL), which will confirm a correct adjustment of the pH electrode.
POOLWATCH TOP
1
2
3
7
5
4
Ref:PoolWatch Top-Eco-29485-gb-W01
6
7
8
9

Capítulos

Tabla de contenido
loading

Tabla de contenido