USEFUL LIFE
The pH, ORP probes has a natural ageing despite you use it according to the rules, the electrode useful life will be between half a year
and two years maximum.
(The pH, ORP probes do not have a guarantee)
STOP OF THE INSTALLATION
.- In
case
the
swimming
switched off and the pH probe and Chlorine cell will be taken out from the chlorine chamber. The pH probe and the chlorine cell
must be cleaned with water, putting in the extremes their plastic protectors and keeping them in their boxes. The holes where the pH
and ORP probes were placed, will be closed with two plastic lids to avoid getting dirty. Protect the PW Top equipment from the dirt
and the humidity.
It is advisable to revise PoolWatch Top Eco Inorganic Chlorine once a year by a specialist technician.
14. GUARANTEE
All the PoolWatch Top Inorganic Chlorine equipment range has a guarantee on material and manufacturing failures for a year. This
guarantee does not include the misuse on the customer's side.
This guarantee does not include in any case the substitution of the detrition elements such as the electrodes.
15. PROBLEMS AND SOLUTIONS POLWATCH TOP ECO INORGANIC CHLORINE
PROBLEMS
pH level above the programmed value
(if enhancer is used)
pH level below the programmed value
(if reducer is used)
Chlorine level above the one
programmed
Chlorine level below the one
programmed.
Led indicator of the pH or Cl pump
dispenser connector or the motorised
valve connector is on, but the
dispenser pump is not working or the
motorised valve is not open.
The motorised valve does not open
and the relay is on
The physicochemical analysis of the
pool water, that is the PoolWatch Top.
Reading (there is too much
difference).
The flow alarm is on
pool
is
not
working
(end of season, repairs, etc.) the PW Top Eco Inorganic Chlorine will be
CAUSES
You selected a % of the dispenser
pump higher than the suitable one.
You selected a % of the dispenser
pump higher than the suitable one.
You selected a % of the dispenser
pump higher than the suitable one.
You selected a % of the dispenser
pump higher than the suitable one.
a)
The connection bridge of the
connectors 1-4 and 2-5 of the grids
connectors has not been done.
b)
Filtering stopped
c)Delay activated
Improper connection
a) Dirty cartridge filter (see pages 5-6
point nº 5)
b) Dirty electrodes
c) Expired electrodes.
d) Unproper photometer reading.
e) High water temperature > 28ºC
a)
There is no water running through
the analysis chamber
b)
Faulty connection to the flow
detector
14
SOLUTIONS
Reduce the % adjusting it to the pool
characteristics.
Reduce the % adjusting it to the pool
characteristics.
Reduce the % adjusting it to the pool
characteristics.
Reduce the % adjusting it to the pool
characteristics.
a)
Do the connection to the connectors 1-4 and 2-5 of
the grid connector.
b)
If the filtering is in automatic mode, wait until it
starts working according to the selected time, or
switch the filtering on manually.
c)Switch off the delay pressing the button 2d.
Review power connection. (See diagram page).
a) Clean
b) Clean them with cleaning solution.
c) Change them.
d) Calibrate photometer
e) Insert the compensating value of water
temperature in the equipment through the
programming.
a) Check the hydraulic circuit circulation of the
PoolWatch Top
b) Verify and do the right connection to the flow
detector.
Ref:PoolWatch Top-Eco-29485-gb-W01