16. TECHNICAL CHARACTERISTICS OF THE POOLWATCH TOP ECO INORGANIC CHLORINE
- Measure range rH (ORP): 0 to 1999 (resolution: 1 unit)
- ORP (rH-mV) Set Point range: 0 to 1999
- Cl Measure range: 0 to 10 (resolution: 0,1 units.)
- Cl Set Point range: 0 to 10 ppm.
- Measure range pH: 0 to 14 (resolution: 0.01 unit)
- pH Set Point range: 0 to 14
- Delay: 10 seconds.
- Calibration to pH 7 and pH 4.
- Calibration to RedOx
- Power consumption of equipment: 5W + dispenser pumps and motorised valve.
- Feed tension: 230 V Monophasic + Earth, 50 Hz
- Commutation hysteresis per time: +/- 10 seconds
TECHNICAL SPECIFICATIONS POOLWATCH TOP INORGANIC CHLORINE
- Controller and/or pH and/or Inorganic Chlorine regulator.
- Visualisation through LCD display backlightened alphanumeric (4lines x 20 characters/line)
- 24 bits dynamotor ADC with balanced lining up of Tª + digital filtering reading to have a high immunity to jamming.
- 16 bits microprocessor.
- 4 regulation outputs ON/OFF (relay) (free power connectors).
- Temperature output.
- Optional output 4-20 mA
- Optional communication output RS485
- Multilanguage programme.
- Warning of faulty electrode in calibration.
- Optoisolated inputs with electrode protection and isolation between probe input (< 6 KV).
It is advisable to make a review once a year by a specialist technician.