WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box or circuit breaker panel before
wiring. All wiring must be in accordance with National
and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
7.1
This Control is designed to operate Only ONE Ceiling
Fan .
NOTE: Electric connections should be in
accordance with the National Electrical Codes and
all Local Codes. Before starting, disconnect power
to the circuit at the main fuse box or circuit breaker
panel.
Remove the Faceplate and Screws from the Existing
Wall Switch . Pull Wall Switch out from Wall Box
(Figure 22) .
7.2
NOTE: Make all wiring connections using
wire connectors (supplied). Make sure that all
connections are tight, including ground, and that
no bare wire is visible at the wire connectors,
except for the ground wire.
NOTE: Set the Fan Control to the OFF position.
WARNING
!
Do not connect any neutral (white) wire to this control.
Incorrect wiring will damage this control.
Connect the Fan Control Black Wire labeled
"TO POWER SUPPLY" to the "HOT" 120V AC Supply
Source Wire . Securely connect Wires with Wire
Connector, supplied (Figure 23) .
Connect the Fan Control Black Wire labeled
"TO FAN" to the "LOAD" Black Wire in Wall Box .
Securely connect Wires with Wire Connector, supplied
(Figure 23) .
Connect the Fan Control Green Ground Wire to the
Supply Ground Conductor (this may be a bare wire or
wire with Green Colored insulation) . Securely connect
Wires with Wire Connector, supplied (Figure 23) .
7. Installing the Wall Control
Determine the "HOT" Wire and the "LOAD" Wire and
disconnect these Wires from the Wall Switch .
NOTE: Do not attempt to disconnect any Wires not
already connected to Existing Wall Switch.
EXISTING WALL SWITCH
SCREWS
SCREWS
Figure 22
TO NEUTRAL
4-SPEED SLIDE
CEILING FAN
CONTROL
OFF
POSITION
L
M 1
M 2
H
O FF
Figure 23
!
Check to see that all connections are tight and that no
bare wires are visible at the wire connectors.
15
WALL BOX
FACEPLATE
TO FAN MOTOR LOAD
1.25 AMP MAXIMUM
BLACK WIRES
BLACK WIRES
TO 120VAC
SOURCE HOT
GREEN GROUND WIRES
WARNING
luminancebrands.com
Please contact 1-800-777-4440 for further assistance
U.L. Model No.: CF500