Fine filter, polyester, area
2
[m
]
Efficiency, fine filter, EN
60335-2-69, Class M [%]
Filter area, HEPA filter [m
Efficiency, fine filter, EN
60335-2-69, Class H [%]
Filter classification, EN
1822-1
Sound level [dB(A)]
Operation
Connection
Connect the machine to an electrical outlet with a voltage as per the machine's rating
plate specifications. If using an extension cord, it must be water-resistant.
Autostart
Connect the power tool to the electrical outlet on the machine. Set the switch to
AUTO. The machine will then automatically start when the tool is used. The machine
turns off a few seconds after the connected tool is powered down. To manually start
the extractor, set the switch to MAN.
Filter cleaning:
The machine has a filter status indicator that lights up when the filter needs to be
cleaned or replaced. The filters must be cleaned 1-2 times a day with continuous use .
Cleaning the filter:
During filter cleaning, the machine should be running and the hose removed from the
suction pipe.
1. Press the connector sleeve against the black stop lug on the exhaust duct or
against the floor in order to produce maximum negative pressure in the cyclone.
Open and close the hatch on the side 3-6 times. Air flows into the machine and
cleans the filter by creating a reverse pulse.
2. Turn off the machine and let the material fall down. Reconnect the suction pipe.
3. Start the machine.
DC 3900a
Turbo
1,8
99,9
2
]
1,5
99,995
HEPA H13
75
DC 3900, Art.nr. 94171-E
DC 3900c
DC 3900c
Turbo
Turbo Twin
1,8
1,8
99,9
99,9
1,5
1,5
99,995
99,995
HEPA H13
HEPA H13
75
75
29