Description; Operation - Dustcontrol DC 3900 Serie Manual Original

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36

Description

The DC 3900 is stable, tough and reliable and
particularly suited to spot extraction where plenty
and easy dust is created. The DC 3900 is suitable
in many different applications ie welding, grinding,
sanding and cleanup.
The DC 3900 is driven by 2 single phase, two
stage fans. The Turbo models are driven by 3
phase turbo pumps.
The extraction system functions with negative
pressure (vacuum) that draws the air through suc-
tion casings/nozzles, hose system, separator and
fi lter system. Coarse separation of dust occurs in
the units cyclone which is a highly effi cient sepa-
rator for larger particulate. The fi ne dust is sepa-
rated and contained by the fi lter system. There is
a jacket mounted at the top of the fi lter cartridge
protecting it from the dust as it enters the cyclone
from the hose. Reverse pulse fi lter cleaning gives
long fi lter life and a consistently high suction capa-
city. The machine is equipped with a HEPA fi lter.
DC 3900 has adjustable cyclone that simplifi es
transport.
DC 3900c:
Material which has been extracted and separated
is collected in a 20 l plastic sack. The sack can be
removed with a simple hand grip. The collected
material is easily handled in this way for disposal
or recycling.

Operation

Connect the unit to a suitable power source, note
requirements on the ID plate. If an extension cord
is to be used, only waterproof cords are accepta-
ble.
The DC 3900 is equipped with a fi lter indication
lamp that indicates when the fi lter needs cleaning
or changing.
The fi lter is generally cleaned once or twice daily
during normal continuous operation. The unit
must be in operation to perform fi lter cleaning.
Loose the tube from the suction pipe and press
the plastic cage against the fl oor so that maximum
pressure is created in the cyclone.
2016-06-21
DC 3900 a uses a cylindrical container to collect
the separated material.
DC 3900 Twin:
The DC 3900 Twin is equipped with a pre-separa-
tor that collects coarse dust in one bag. This bag
will be fi lled faster than the other bag, where fi ne
dust is collected.
DC 3900L:
The machine is equipped with a fl exible bag sys-
tem, in which the dust is collected in a permanently
closed system.
Open the port on the side of the unit three to six
times. This reverse pulse of air cleans the fi lter.
DC 3900c:
The plastic sack should be changed only after the
fi lter has been cleaned. The sack should be chan-
ged when the dust level is about 5 cm under the
foot valve. The plastic sack should be sealed after
removal from the machine.
Use only original plastic sacks
DC 3900a
The container under the cyclone should be emp-
tied when it is fi lled to ca 2/3.
DC 3900- 12
Part No 94171-C
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Dc 3900cDc 3900aDc 3900l

Tabla de contenido